Omron V640 User Manual page 45

V640 series amplifier unit, cidrw head, cidrw controller, cidrw controller
Hide thumbs Also See for V640:
Table of Contents

Advertisement

■ Multi-connection port
The method for connecting to an Amplifier Unit is explained here.
Link Unit
To multi-connection port
• Connector
Pin No.
Name
5
-
4
+
3
GR
2
-
1
+
To the RS-485 port
Function
No wiring is required. (Short with terminal 2 within the circuit)
No wiring is required. (Short with terminal 1 within the circuit)
Ground to 100 Ω or less.
Connect to the minus line of the Amplifier Unit.
Connect to the plus line of the Amplifier Unit.
Installation and Connections/Wiring
Amplifier Unit
SECTION 2
CIDRW System
41
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

V640-ham12V640-hs62V700-l22V700-l11

Table of Contents