Specify the parameters to be changed.
When the first parameter is specified, the ALARMS indicator flashes.
2.
Confirm the parameter change.
The input parameter is checked and written.
■ Check for Correct Setting
The currently set data can be output so that you can check if it is correct.
1.
Send the parameter output command "::GET_E99SYS"
from the host device.
The carrier ID settings are displayed.
Do not change operation parameters other than RT, CIDOF, and CIDLN.
This can cause the system to stop operating correctly.

Change the data segment area

The data segment area (memory map) must be changed to communicate with ID Tags (RI-TRP-DR2B/
RI-TRP-WR2B, made by Texas Instruments). The procedure for changing the data segment area is
explained here.
Data Segment Area
The commands, and the parameters that can be set, are indicated below.
List of Commands
Designation
Parameter designation
Parameter confirmation ::END
Comment
Refer to page 125.
Command input
(Tag name) = (Set value) <CRLF> Specify the parameter value corresponding to the tag name.
# (Comment) <CRLF>
or
CRLF
Preparing for Communications
CIDOF=0
CIDLN=16
::END
_
::GET_E99SYS
RT=10.0
CT=0.1
RTY=3
DINST=
MENT=
MODEL=L22
HREV=001.04
CIDOF=00
CIDLN=16
::END
_
Explanation
Checks the parameter designations that have been received so
far and, if there is no error, confirms the settings.
This is ignored as the comment line.