Set the Communications Conditions for Amplifier Units

Set the communications conditions using the DIP switches on the side face of the Amplifier Unit.
After changing the DIP switch settings, restart the system. The new settings will not become effective until the
system is restarted.
Node No.
Node No.
1
2
01
OFF
OFF
02
ON
OFF
03
OFF
ON
04
ON
ON
05
OFF
OFF
06
ON
OFF
07
OFF
ON
08
ON
ON
09
OFF
OFF
10
ON
OFF
11
OFF
ON
12
ON
ON
13
OFF
OFF
14
ON
OFF
15
OFF
ON
16
ON
ON
Always set node numbers that are unique within the system configuration. When SECS is used, the node number set here is
"HeadID(E99)."
Baud rate
Option
38400 bps
19200 bps
9600 bps (default setting)
4800 bps
RS-485 terminator
DIP-SW
Option
10
Invalid
OFF
Set ON at both of the end units in a multidrop system, and OFF at all the other units. If there is only one
unit, set ON.
Valid
ON
If there is a possibility that one of multiple Amplifier Units in use may be used independently, turn the termi-
nators of all the Amplifier Units OFF and fit external terminators close to the units at both ends.
DIP-SW
3
4
5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
DIP-SW
6
7
ON
ON
Use a consistent baud rate setting within the same system configuration.
OFF
ON
OFF
OFF
ON
OFF
Preparing for Communications
Node No. Baud rate
RS-485 terminator
Always OFF
(Not used in this CIDRW system)
Node No.
1
17
OFF
18
ON
19
OFF
20
ON
21
OFF
22
ON
23
OFF
24
ON
25
OFF
26
ON
27
OFF
28
ON
29
OFF
30
ON
31
OFF
1:1 protocol
ON
Description
Description
SECTION 3
DIP-SW
2
3
4
5
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
CIDRW System