SECTION 4
Reading from/Writing to ID Tags
The command and response code details provided here are for 1:N protocol. The command format for 1:1
protocol is obtained by omitting the SOH, node number, and FCS data, as described in the previous pages.
■ READ
Reads any pages of data from the ID Tag. The maximum number of pages that can be read at one time
is 16.
Command
SOH
Node No.
01h
Bit
7
-
Page
Sys
-
0*
0*
Designation
Value
00
* Always specify 0. If you specify 1 an error (Response code: 14) will occur.
Parameter description
Parameter
Page designation
Data Segment Area
The response code (when normal: 00) and the data in the specified pages are returned in ascending order of
page numbers.
Response
Response
SOH
Node No.
01h
0
Example: Reading the data of pages 1 and 3 of node No.1
Data content of the ID Tag
Page 1
Page 2
Page 3
Page 4
CIDRW System
80
User's Manual
Command code
0
1
0
0
0
7
-
3
2
1
Sys Sys
-
Sys
17
16
0*
0*
0*
0/1
0/1
00 - 07
Pages are specified by setting the bits corresponding to pages that are to be read to 1 and setting
the other bits to 0, then converting the result to a hexadecimal character string.
Refer to page 125.
Page n
code
Data 1
⋅ ⋅ ⋅
0
12h
34h
56h
78h
11h
22h
33h
44h
Page designation (8 characters)
0
7
6
-
1
15
14
13
-
8
0/1
0/1
0/1
•••
0/1
00 - FF
Description
Read data
⋅ ⋅ ⋅
Data 8
Data 1
90h
12h
34h
56h
55h
66h
77h
88h
FCS
0
7
6
-
2
1
7
6
5
-
1
Sys Sys
0/1
0/1
0/1
•••
0/1
0*
00 - FC
Page m (n<m)
FCS
⋅ ⋅ ⋅
Data 8
CR
0Dh
0
0*
CR
0Dh

Advertisement