Omron V640 User Manual page 51

V640 series amplifier unit, cidrw head, cidrw controller, cidrw controller
Hide thumbs Also See for V640:
Table of Contents

Advertisement

1.
Specify the parameters to be changed.
When the first parameter is specified, the ALARMS indicator flashes.
2.
Confirm the parameter change.
The input parameter is checked and written.
When writing is completed, a message indicating the result is displayed.
The ALARMS indicator lights.
If writing is completed with an error, the parameters are not updated.
The figure in square brackets [ ] indicates the line number where the
error was first detected. If a parity error is detected in the received char-
acters, this figure is [0].
Check the sent data based on this information.
A text file is created based on the data that is keyed in, as shown below, and this data can be conveniently transmitted
using the terminal's text file send function.
When writing is completed without error
Example: PRM.TXT
#Parameter Setting File for SystemA
#Protocol
S_BAUD=19200
S_DEVID=1
#SECS
S_BNO=0
::END
Preparing for Communications
S_BAUD=19200
S_DEVID=1
S_BNO=0
_
::END
_
SETUP_COMPLETE
_
When writing is completed with an error
SETUP_FAILED [2]_
CIDRW System
SECTION 3
47
User's Manual