Services and Addresses

6-4

Services and Addresses

FINS-mini Command
Services
Addresses
Variable Type CE/8E (Monitor Level Parameters)
Address
Data
0000
Input Monitor
0001
Duty Monitor
0002
Output Monitor
0003
Phase Angle Monitor
0004
Current Monitor
0005
Total Run Time Monitor
0006
Status
0007
Not used.
0008
Not used.
0009
Not used.
0010
Not used.
0011
Not used.
0012
Not used.
0013
Not used.
0014
Version
76
MRC SRC
Service
01
01
Variable Area Read
01
02
Variable Area Write
05
03
Controller Attribute Read Reads the model number and communica-
06
01
Controller Status Read
08
01
Echo-back Test
30
05
Operation Command
Note Service requests will not be accepted and no response will be re-
turned if there is a RAM error or the Controller is in standby status.
(Standby status exists from when power is turned ON until normal
operation is possible.)
Data range
H'00000000 to H'000003E8
H'00000000 to H'000003E8
H'00000000 to H'000003E8
H'00000000 to H'000003E8
H'00000000 to H'000002EE
H'00000000 to H'000003E7
H'00000000 to H'00000***
Always 0.
Always 0.
Always 0.
Always 0.
Always 0.
Always 0.
Always 0.
H'00000000 to H'00000***
* The data ranges apply to all models of the G3PW.
Reads data from the variable area.
Writes data to the variable area.
tions buffer size of the Controller.
Reads operating status.
Performs an echo-back test.
Performs operation commands, such as
resetting and changing areas.
*
Notation
The data range is ten times
the actual values.
Bit fields
0
0
0
0
0
0
0
1.23 = 00000123
Section 6-4