Operating Guide | iC7-Marine PROFINET
Table 16: General Connectivity Settings for Propulsion & Machinery (continued)
Menu index
2.12.13.6
2.12.13.7
Table 17: Event Descriptions for Propulsion & Machinery
Value
Info
Warning
Fault, Ramp to Coast
Fault, Coast
32
| Danfoss Drives Oy © 2024.04
Parameter
Parameter number
Fieldbus Watchdog
5246
Start Delay
FB Monitoring Ctrl.
1338
Place Dependency
Description
The event is logged in the event log.
The drive issues a warning.
The drive issues a fault, ramps down, and coasts.
The drive issues a fault and coasts the motor.
Value
Description
0.00–3000 s
Set a delay time for af-
ter which the fieldbus
(Default: 30.00 s)
watchdog event is trig-
gered if the watchdog
bit has not changed its
value. This time applies
only immediately after
powering the control
unit of the drive.
• Disabled
Set the control place
• Enabled
dependency for
Fieldbus Fault, Process
Data Timeout, and
Fieldbus Watchdog.
When enabled, these
functions are active
only in the fieldbus
control place. When
disabled, these
functions are active
regardless of the
control place.
AQ481922043454en-000101 / 172K4282A
Need help?
Do you have a question about the iC7-Marine PROFINET and is the answer not in the manual?