Installation
WARNING ALWAYS USE J.A. ROBY PARTS on your
appliance. Using other differences parts can damage the
appliance and cause injury.
Fire Prevention
Smoke and carbon monoxide emissions
and monitors
To provide reasonable fire prevention, the following should be
given serious consideration:
1. At least one smoke detector on each floor of your home
should be installed to ensure your safety. They should be
located away from the heating appliance and close to the
sleeping areas. Follow the smoke detector manufacturer's
placement and installation instructions, and be sure to
maintain regularly.
2. A conveniently located Class A fire extinguisher to contend
with small fires resulting from burning embers.
3. A CO detector should be installed in the room with the
appliance.
4. A practiced evacuation plan, consisting of at least two
escape routes.
5. A plan to deal with a chimney fire as follows:
a. In the event of a chimney fire:
b. Evacuate the house immediately
c. Notify fire department.
The average of the CO emission (carbon monoxide) is 1.06
g/min. To maintain this rate, it's recommended to operate the
appliance in low or medium burn rate.
The hazards with some fuels (e.g., charcoal) and the
possibilities of generating carbon monoxide and the hazards
from carbon monoxides.
When the smoke detector is activated is mean that the
smoke spill out of the appliance. Verify the door is close
and the draft in chimney is good.
Floor protection
Your stove must be installed on a plate of non-combustible
material to protect the floor and avoid fire caused by:
•
Projections of sparks at the moment of opening the
door and loading,
•
The heat radiation of runaway which might cause self-
ignition of floor and surface.
•
Possible creosote flow when there is a chimney fire.
(Example: cement, brick, ceramic tiles, steel plate, etc.)
Do not store any fuel below the chamber combustion
Do not store solid fuel on the ember protection plate
The FORGEUR and FORGEUR CLASSIQUE
model are not approved to store wood inside the
pedestal.
PR_I028/2023-08-08-EN
Minimum dimension of floor protection
plate
The following dimensions are the minimum values.
Canada:
• 41 7/8 inches (106.4 cm)
• 47 5/8 inches (121 cm)
Clearances chart on floor plate
The following dimensions are the minimums values.
Canada:
• 8 inches (20.3 cm) rear
• 8 inches (20.3 cm) side
• 18 inches (45.7 cm) loading door