Transportable Building Installation - J. A. Roby FORGERON CLASSIQUE Instruction Manual

Table of Contents

Advertisement

Transportable building installation

DANGER: DO NOT INSTALL IN BEDROOM.
WARNING: THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST
BE MAINTAINED.
1)
Do the General stove installation steps 1 to 11.
2)
The following requirements are MANDATORY for
installation in a mobile home.
a. The exterior air intake must be installed.
b. The stove must be fixed onto floor of mobile home
with bolt and nuts.
c. The stove must be electrically grounded to
chassis of the mobile home.
d. All of the following equipment must be certified
and approved for mobile home installation.
• The chimney system
• The roof flashing
• The Storm collar
• Cap with spark arrester
• Firewall
• Chimney ceiling support
• Decorative collar
e.
If the chimney is exposed outside from a wall
and placed lower than 7 feet (213 cm) above
the ground level where the mobile home is
situated. A shield must be installed around
chimney from the bottom to 7 feet (213 cm)
tall. If openings are made into the shield they
must be less than ¾ inch (2 cm) wide and
PR_I028/2023-08-08-EN
3)
Always keep the door closed and lock. Open it only
when add wood or start fire.
4)
To close the exterior air inlet, a damper must be
installed in the air intake pipe.
Don't forget to open the damper when operate your
5)
stove so that the smoke will not enter the house.
6)
Always use certified parts for mobile home. Never use
a substitute.
The chimney shall be provided with a spark arrester secured to
the chimney. The net free area of the arrester above the
chimney outlet shall be not less than four times the net area of
the chimney outlet, and the vertical height of the arrester above
the chimney outlet shall be not less than one-half the diameter
of the chimney flue. Opening shall not permit the passage of a
sphere having a diameter larger than ½ inch (12.7mm) and
shall permit the passage of a sphere having a diameter of 3/8
inch (9.6mm)
When the space heater is installed in a transportable building,
you need to remove the chimney for transportation.
Revision : 10
keep the distance of 4 inches (10,2 cm) or
more in order to avoid contact with chimney.
f.
The chimney must exceed at least 3 feet (91,4
cm) from the highest point of opening made in
the roof.
g.
Make sure to seal correctly the flashing of the
roof, the firewall and the exterior air inlet.
24