Maintenance Instructions; General Vent Maintenance; Log Replacement; Glass - Regency City CST50E Owners & Installation Manual

Direct vent
Table of Contents

Advertisement

Maintenance Instructions

1. Always turn off the gas valve before cleaning.
For relighting, refer to lighting instructions. Keep
the burner and control compartment clean by
brushing and vacuuming it at least once a year.
When cleaning the logs, use a soft, clean paint
brush as the logs are fragile and easily damaged.
2. Clean appliance and door with a damp cloth
(never when unit is hot). Never use an abrasive
cleaner. The glass should be cleaned with a gas
fireplace glass cleaner. The glass should be
cleaned when it starts looking cloudy.
3. The fireplace is finished in a heat resistant paint
and should only be refinished with heat resistant
paint. Regency
uses StoveBright Paint - Metallic
®
Black #6309.
4. Periodically check the burner for proper
positioning and condition. Visually check the
flame of the burner periodically, making sure
the flames are steady, not lifting or floating.
If there is a problem, call a qualified service
person.
5. The appliance and venting system must be
inspected before use and at least annually by
a qualified field service person, to ensure that
the flow of combustion and ventilation air is not
obstructed.
6. Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and replace
any part of the control system and gas control
which has been under water.
7. In the event this appliance has been
serviced, check that the vent-air system was
resealed & reinstalled in accordance with the
manufacturer's instructions.
8. Verify operation after servicing.

General Vent Maintenance

Conduct an inspection of the venting system
semi-annually. Recommended inspection areas
are listed below.
1. Check the venting system for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.
2. Remove the cap and shine a flashlight down the
vent. Remove any bird nests or other foreign
material.
3. Check for evidence of excessive condensation,
such as water droplets forming in the inner
liner and dripping out the joints. Continuous
condensation can cause corrosion of caps,
pipes, and fittings. It may be caused by having
excessive lateral runs, too many elbows, and
exterior portions of the system exposed to cold
weather.
4. Inspect joints to verify that no pipe sections
or fittings were disturbed or loosened. Also
check mechanical supports such as wall straps
or plumbers' tape for rigidity.

Log Replacement

The appliance should never be used with broken
logs. Turn off the gas valve and allow the unit to cool
before opening the door and removing the logs. If
a log needs replacement, you must use the proper
replacement log. The position of these logs must
be as shown in the diagrams under log installation.

Glass

Improper positioning of logs may create
carbon build-up and will alter the appliance's
performance. Resulting damage is not covered
under warranty.
Your Regency
fireplace is supplied with high
®
temperature 5mm tempered outer glass & 5mm
ceramic inner glass. If your glass requires cleaning,
we recommend using an approved glass cleaner
sold by an authorized dealer. Do not use abrassive
materials or ammonia-based cleaners.
• Do not clean the glass when it
is hot.
• The use of substitute glass will
void all product warranties.
• Do not strike the glass.
• Do not operate this fireplace with
a cracked, broken, or missing
glass front.
Wear gloves and safety glasses
when removing damaged or
broken glass.
• Replacement of glass panels
should be done by a licensed or
qualified service person.

Glass Replacement

In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only. Replacement glass is shipped
already installed into the door frame. Reinstall as per
the instructions in the "Glass Installation" section.
Replacement Glass Part
Numbers
Outer Safety Glass Front - Tempered
(Part# 940-554/P each)
Inner Glass - Ceramic (Part# 940-555/P each)
owner's information
City Series CST50E |
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

City seriesCity cst50e-ngCity cst50e-lp

Table of Contents