Chapter 3: Calibration

3.4 Dealer calibration

Response settings

Wind speed

The Dealer calibration procedures enable the following parameters to
be set:
• Wind angle and speed response.
• Wind speed calibration.
• Boat show mode on/off.
Dealer calibration also gives access to the Factory defaults screen. This
enables you to re-apply the factory settings if you want to reset the
instrument to a known operating condition.
To commence Dealer calibration, hold down the
together for approximately 12 seconds, to select the Dealer calibration
entry page (see Dealer calibration diagram, sheets 1 and 2). Then
momentarily press the < and > keys to proceed with the calibration. As
the calibration progresses, use the
screen.
The response values for wind speed and angle, determine the
frequency at which information is updated. A low number provides a
smooth response and a high number a much livelier response with
rapid pointer movement.
Use the < < < < < (decrement) and > > > > > (increment) keys to set the required
value. Response values are from 1 to 15.
The Wind speed and Wind speed calibration screens are used to set the
correct value for the wind speed. On entry (from the Wind speed
response screen), the current value for wind speed is displayed. Set the
correct wind speed value, by applying a calibration factor as follows:
1. Use the < < < < < (decrement) and > > > > > (increment) keys to switch from the
Wind speed screen to the Wind speed calibration screen.
2. Use the < < < < < (decrement) and > > > > > (increment) keys to set the wind
speed calibration factor. Calibration factor values range from 0.75
to 1.25 in 0.01 steps.
3. Timeout to the Wind Speed screen, and if further adjustment is
necessary, repeat steps 1 and 2.