Flush Mounting Procedure - Raytheon ST60 Owner's Handbook Manual

Hide thumbs Also See for ST60:
Table of Contents

Advertisement

Chapter 2: Installation
Fitting the low profile bezel

Flush mounting procedure

Flush mount your instrument ( see the Flush mounting illustration) as
follows:
1. Assemble the ST60 instrument and low-profile bezel as described
under Fitting the low-profile bezel.
2. Ensure that:
• The panel on which you intend to mount the instrument is
between 3 mm and 20 mm thickness.
• The selected location is clean, smooth and flat.
• There is sufficient space behind the location to accommodate
the rear of the instrument and connectors.
3. Apply the flush mount template (supplied at the rear of this
handbook) to the selected location and mark out the aperture into
which the assembled instrument and bezel will sit.
4. Cut out the aperture (3) for the assembled instrument and bezel
and remove the template.
5. Peel off the protective sheet from the self-adhesive gasket (4) then
stick the gasket into position on the rear of the bezel.
8
7
13
9
D4509-1