Chapter 4: Calibration

4.4 Dealer calibration

The Dealer calibration procedures enable the following parameters to
be set:

• User calibration on/off.

• Response settings for speed, depth heading wind angle, wind speed,
Dealer calibration also gives access to the Factory defaults screen. This
enables you to re-apply the factory settings if you want to reset the
instrument to a known operating condition.
To commence Dealer calibration, hold down the
together for approximately 12 seconds, to select the Dealer calibration
entry page (see Dealer calibration diagram). Then press the track and
reset keys together, to start the calibration.
User calibration on/off
Press the track and reset keys to toggle the User calibration either ON
or OFF as required. With OFF selected, User calibration and
Intermediate calibration are both disabled.

Response settings

The response values determine how often displayed information is
updated. A low number provides a smooth response and a high
number a much livelier response. The screen title shows which
response you are setting, and when you have set one response, press
the
For each response function, use the track (decrement) and reset
(increment) keys to set the required value. Response values are from 1
to 15.
The screen titles and associated response functions are displayed in the
following sequence:
Title
BOAT SPD
DEPTH
HEADING
VMG, course over ground and speed over ground.
key to display and set the next.
Response function
Speed
Depth
Heading
33
and
keys
continued ...