Raytheon ST60 Owner's Handbook Manual
Raytheon ST60 Owner's Handbook Manual

Raytheon ST60 Owner's Handbook Manual

Tridata instrument
Hide thumbs Also See for ST60:
Table of Contents

Advertisement

Quick Links

ST60 Tridata
Instrument
Owner's
Handbook
Document number: 81040_2
Date: 1st September 1999

Advertisement

Table of Contents
loading

Summary of Contents for Raytheon ST60

  • Page 1 ST60 Tridata Instrument Owner’s Handbook Document number: 81040_2 Date: 1st September 1999...
  • Page 3: Table Of Contents

    Introduction Contents Introduction ................v EMC conformance ............v Data inputs ............... vi SeaTalk ............... vi Stand alone operation ..........vi Remote control ..............vi Mounting options ............vii Parts supplied ..............viii Chapter 1: Operation ............. 1 1.1 Getting started ............. 1 Calibration requirement ..........
  • Page 4 ST60 Tridata Instrument Owner’s Handbook 1.3 Alarms ................. 7 1.4 Display settings ............7 Illumination ..............7 Contrast ............... 7 1.5 Remote control ............8 Chapter 2: Maintenance and Fault Finding ......9 2.1 Maintenance ..............9 Servicing and safety ............ 9 Instrument ..............
  • Page 5 Introduction Bracket mounting ..........22 Fitting transducer ............22 Running transducer cable ........22 Connecting the instrument ........23 Types of connection ..........23 Signal connections ..........23 Power supply connections ........24 SeaTalk systems ..........24 Stand alone instruments ......... 25 Chapter 4: Calibration ............
  • Page 6 ST60 Tridata Instrument Owner’s Handbook 4.3 Intermediate calibration ..........34 Speed calibration ............35 Leaving Intermediate calibration ......39 4.4 Dealer calibration ............39 User calibration on/off ..........39 Response settings ............39 Boat show mode ............41 Factory defaults ............41...
  • Page 7: Introduction

    Introduction Introduction Thank you for purchasing a Raytheon product. We are sure your ST60 instrument will give you many years of trouble-free operation. This handbook describes how to install and use the Raytheon ST60 Tridata instrument. This instrument provides accurate depth, speed, trip and timer information, on a high quality Liquid Crystal Display (LCD).
  • Page 8: Data Inputs

    ST60 Tridata Instrument Owner’s Handbook Data inputs The ST60 Tridata instrument can fulfil master and/or repeater roles by receiving data either from the appropriate transducers and/or from a SeaTalk instrumentation system. SeaTalk SeaTalk enables a number of compatible instruments to operate as a single, integrated navigational system.
  • Page 9: Mounting Options

    Introduction Mounting options If you do not want to surface mount your ST60 instrument, options are available for: • Flush mounting. If you have ordered the flush mounting option a low-profile bezel and four fixing screws are also provided. • Bracket mounting.
  • Page 10: Parts Supplied

    Spare spade terminals are also provided, to re-terminate transducer cables if they have to be cut to facilitate installation. Note: The above packing list is for an ST60 Tridata system. Where an instrument is purchased separately, Speed and Depth transducers are...
  • Page 11 Introduction TRIDATA ST60 Worldwide depth speed trip Tridata Distributors Current Boat speed depth Instrument Owner's Trip Handbook Maximum Shallow Alarm speed Threshold reset 3s to Reset Water temperature reset 3s to Reset Deep Average speed alarm threshold Document Number: 44421_10...
  • Page 12 ST60 Tridata Instrument Owner’s Handbook...
  • Page 13: Chapter 1: Operation

    Screen layout D4424-1 1.2 Normal operation Use the flow charts in this Chapter to operate your ST60 Tridata instrument. Flow charts are provided for: • Using the depth key. This gives access to current depth information. On master instruments, this also gives access to depth alarm threshold information, and allows you to set the alarm thresholds.
  • Page 14: Depth

    ST60 Tridata Instrument Owner’s Handbook • Using the speed key. This gives access to maximum speed, average speed and Velocity Made Good (VMG) to windward. • Using the trip key to gain access to log, trip, water temperature and timer information.
  • Page 15: Depth Alarm Threshold Displays

    Chapter 1: Operation If for any reason depth information is lost, the DEPTH title will flash once per second and the displayed depth value will be the last good reading. Depth alarm threshold displays The alarm threshold displays are available if the instrument is operating as a master.
  • Page 16: Maximum Speed

    ST60 Tridata Instrument Owner’s Handbook Boat speed speed speed VMG to Maximum windward speed speed speed Average speed Using the speed key D4414-1 Maximum speed The screen shows the maximum speed attained since the last reset. The maximum speed value is reset automatically at power-up. If the instrument is operating as a master, the maximum speed can also be reset manually by pressing the reset key for 2 seconds.
  • Page 17: Trip

    Chapter 1: Operation Trip The trip key gives access to log, trip, water temperature and timer displays, as shown in the Using the trip key illustration. trip trip 10 minute race start Trip timer trip trip 5 minute Water race start temperature timer trip...
  • Page 18: Water Temperature

    ST60 Tridata Instrument Owner’s Handbook Water temperature The water temperature is shown in either degrees Celsius (°C) or Fahrenheit (°F), as set during calibration (see Chapter 4, Calibration). Timers Three timers are available: • Count-up timer. • 5-minute race start.
  • Page 19: Alarms

    Chapter 1: Operation 1.3 Alarms An alarm condition occurs if: • The depth is less than the SHALLOW or SHALLOW anchor threshold. • The depth is greater than the DEEP anchor threshold. • The depth crosses the DEEP threshold. An alarm condition is indicated by an alarm buzzer and a flashing alarm symbol (bell icon) on the display.
  • Page 20: Remote Control

    1.5 Remote control When it is connected to SeaTalk, the ST60 Tridata instrument can be controlled remotely with a SeaTalk Remote Keypad Unit. Remote control of an instrument is indicated by a REMOTE legend on the display, to indicate that the keypad has control.
  • Page 21: Chapter 2: Maintenance And Fault Finding

    This will not harm the instrument and can be cleared by increasing the illumination to the brightest setting. Periodically clean your ST60 instrument with a soft damp cloth. Do NOT use chemical and abrasive materials to clean the instrument.
  • Page 22: Fault Finding

    Changes in the electronic environment may adversely affect the operation of your ST60 equipment. Typical examples of such changes are: • Electrical equipment has recently been installed or moved aboard your vessel. • You are in the vicinity of another vessel or shore station emitting radio signals.
  • Page 23 If you are unable to rectify a problem, contact the Raytheon Product Support Department or your own National Distributor, for assistance.
  • Page 24 ST60 Tridata Instrument Owner’s Handbook...
  • Page 25: Chapter 3: Installation

    Chapter 3: Installation Chapter 3: Installation This chapter describes how to install the ST60 Tridata instrument, and associated speed and depth transducers. The transducers are fitted in the hull of the vessel and connected to the rear of the instrument. The actual type of transducers depends on the type of hull in which they are to be installed.
  • Page 26 Other transducer types are also available for specific requirements. For further details, contact your local Raytheon dealer. For accurate speed and depth readings the transducers should be sited within the clear water flow areas indicated by the shaded areas in the following diagram.
  • Page 27: Instrument

    ST60 instruments can be fitted either above or below deck, provided the rear of the instrument is sited where it is protected from contact with water.
  • Page 28: Emc Guidelines

    To minimise the risk of operating problems: • All Raytheon equipment and cables connected to it should be: • At least 1 m (3 feet) from any equipment transmitting or cables carrying radio signals, e.g. VHF radios, cables and antennas. In the case of SSB radios, the distance should be increased to 2 m (7 ft).
  • Page 29: Suppression Ferrites

    If your Raytheon equipment is going to be connected to other equipment using a cable not supplied by Raytheon, a suppression ferrite MUST always be fitted to the cable close to the Raytheon unit. 3.2 Procedures As it is not possible to describe procedures for all possible installation...
  • Page 30: Unpacking

    Fitting the instrument The ST60 Tridata instrument can be installed using one of a number of different mounting options: • Surface mounting. Gives a profile of approximately 24 mm.
  • Page 31: Flush Mounting

    Fitting the low-profile bezel Fitting the low-profile bezel In order to flush-mount your ST60 instrument, you must first replace the standard bezel with the low-profile bezel as follows: 1. Hold the instrument in both hands with the display towards you.
  • Page 32: Flush Mounting Procedure

    Flush mounting procedure Flush mounting procedure Flush mounting procedure Flush mounting procedure Flush mounting procedure Flush mount your instrument ( see the Flush mounting illustration) as follows: 1. Assemble the ST60 instrument and low-profile bezel as described under Fitting the low-profile bezel.
  • Page 33 Chapter 3: Installation 2. Ensure that: • The panel on which you intend to mount the instrument is between 3 mm and 20 mm thickness. • The selected location is clean, smooth and flat. • There is sufficient space behind the location to accommodate the rear of the instrument and connectors.
  • Page 34: Bracket Mounting

    To bracket mount your ST60 instrument, do so in accordance with the Control Unit Mounting Bracket Instruction Sheet.
  • Page 35: Connecting The Instrument

    4 mm 3 mm Preparing wire for connection D4467-2 Observing the above guidelines, run the transducer cable to the ST60 Tridata instrument. Connecting the instrument Types of connection The ST60 Tridata instrument, can be connected: • As a stand-alone, master instrument connected directly to a Speed and/or Depth transducer.
  • Page 36: Power Supply Connections

    Black Brown Screen Blue White Screen Cable from Depth transducer Green Cable from Speed transducer Connections to ST60 Tri Data instrument D4423-1 Power supply connections SeaTalk systems SeaTalk systems SeaTalk systems SeaTalk systems SeaTalk systems CAUTION When instruments are connected to SeaTalk, ensure that the power supply for the SeaTalk 12 V line is protected by a 5 A fuse.
  • Page 37: Stand Alone Instruments

    Chapter 3: Installation 5 A fused, 12 V dc supply (typically provided by autopilot) Screen Instruments 5 to 16 Screen SeaTalk power connections D4311-1 Stand alone instruments Stand alone instruments Stand alone instruments Stand alone instruments Stand alone instruments Stand-alone instruments are not connected to SeaTalk and therefore need to be connected to an alternative 12 V power source.
  • Page 38 ST60 Tridata Instrument Owner’s Handbook...
  • Page 39: Chapter 4: Calibration

    Chapter 4: Calibration Chapter 4: Calibration 4.1 Introduction The ST60 Tridata instrument is set up with factory-programmed default settings, so in order to optimise the performance of the instrument on board a particular vessel, the procedures in this Chapter must be carried out immediately after the completion of installation and before the equipment is used for navigational purposes.
  • Page 40: User Calibration

    • Set timer alarm buzzer on or off. Separate routines are provided for the User calibration of the depth and speed functions. To carry out either of these routines: 1. Power up the ST60 Tridata instrument. To start User calibration hold down...
  • Page 41: Depth

    Chapter 4: Calibration 2. Press the depth and speed keys for approximately 2 seconds so that the User calibration entry screen is displayed. 3. Carry out the User calibration procedures for Depth and Speed. Depth To calibrate the depth functions: 1.
  • Page 42: Depth Offset

    ST60 Tridata Instrument Owner’s Handbook Depth offset WARNING: The use of incorrect offset values could result in misleading depth information being displayed with a consequent risk of running aground. Depths are measured from the transducer to the sea bed. However, you...
  • Page 43: Shallow Alarm Lock

    Chapter 4: Calibration • If you want to apply a keel offset, adjust the displayed reading until the appropriate negative offset value is shown. Shallow alarm lock When set to on, prevents alteration to the shallow depth alarm threshold. Speed To calibrate the speed functions: 1.
  • Page 44 ST60 Tridata Instrument Owner’s Handbook From User calibration start screen Set speed Set timer alarm units speed speed Temperature calibration speed Set speed resolution speed Set temperature speed units Set log units Setting the correct speed Adjust to SOG If SOG...
  • Page 45: Adjust To Sog

    Set temperature units Select either °C or °F, as required. Temperature calibration Set the display to show the current water temperature. Timer alarm buzzer Switches the count-up and race-start timer audible alarm on the ST60 Tridata instrument being calibrated, on and off.
  • Page 46: Leaving User Calibration

    ST60 Tridata Instrument Owner’s Handbook Leaving User calibration Hold down the depth and speed keys for 2 seconds, to save your settings, exit User calibration and resume normal operation. 4.3 Intermediate calibration Intermediate calibration enables you to: • Check the instrument software version.
  • Page 47: Speed Calibration

    The speed calibration procedure involves carrying out two runs over a measured distance, to enable a calibration factor to be determined and applied to your ST60 Tridata instrument, to ensure optimum accuracy. Each calibration run comprises outward and return legs, to minimise...
  • Page 48 ST60 Tridata Instrument Owner’s Handbook Note: It is recommended that the speed calibration procedure is carried out in conditions of minimum tidal drift. To carry out a speed calibration, start the Intermediate calibration procedure and use the speed key to proceed to the Calibration run length screen (see sheet 1 of the Speed calibration flow chart).
  • Page 49 Chapter 4: Calibration from Intermediate calibration (Instrument status display) either Calibration run length trip reset to set length of calibration run trip reset trip reset At the start of the outward cal run press Carry out the outward leg of speed the first cal run At the end...
  • Page 50 ST60 Tridata Instrument Owner’s Handbook At the start of the outward cal run press Carry out the from Speed outward leg of calibration - sheet 1 speed the second cal run At the end of the speed outward cal run...
  • Page 51: Leaving Intermediate Calibration

    Chapter 4: Calibration Leaving Intermediate calibration Hold down the depth and speed keys for 2 seconds, to save your settings, exit Intermediate calibration and resume normal operation. 4.4 Dealer calibration The Dealer calibration procedures enable the following parameters to be set: •...
  • Page 52 ST60 Tridata Instrument Owner’s Handbook depth speed Hold down for approximately 12 seconds trip reset Calibration on/off depth depth Speed Factory response defaults At each screen use either trip reset to set the required values depth depth Boat show mode...
  • Page 53: Boat Show Mode

    Chapter 4: Calibration Boat show mode CAUTION: Do NOT enable this mode. It must only be used for demonstration purposes. Ensure that the Boatshow Mode Use is set to OFF. If necessary, use the trip trip trip or reset reset reset reset key to achieve this.
  • Page 54 ST60 Tridata Instrument Owner’s Handbook 81040-2...
  • Page 55 Drill 5mm (3/16in) diameter ST60 Surface Mount Template Machine hole 90mm (3.54in) diameter Shaded areas to be removed Drill 5mm (3/16in) diameter D4436-1...
  • Page 57 ST60 Flush Mount Template 4 holes 6 mm diameter Shaded area to be removed 109 mm D4437-1...
  • Page 59 During this period, except for certain products, travel costs (auto mileage and tolls) up to 100 round trip highway miles and travel time of 2 hours, will be assumed by Raytheon Marine Company only on products where proof of installation or commission by authorised service agents, can be shown.
  • Page 60 United States of America Raytheon Marine Company 603-647-7530 Recreational Products 603-634-4756 676 Island Pond Road Manchester, NH 03109-5420 U.S.A. UK, Europe, Middle East, Far East Raytheon Marine Company (44) 1705 693611 Recreational Products (44) 1705 694642 Anchorage Park, Portsmouth Customer support (44) 1705 661228...

Table of Contents