Supervisor level
Enter your message for your planned maintenance work. You can edit one, two or all three
of the 1/2/3 messages.
Reset display
The message appears until the display is permanently reset. The message then appears
again once the next interval is reached.
External applications
External exhaust flap
External hardware is connected via the Miele Connector Box.
The time delay between the external exhaust air flap's activation point and the switch-on
time for the drum/fan motor is regulated.
A message appears in the display while the exhaust air flap is open.
- Factory default: off
This option must always be selected if there is no exhaust air flap to activate. This pre-
vents the programme from being cancelled.
- On (1 second to 5 minutes)
Additional fan
External hardware is connected via the Miele Connector Box.
The additional fan is switched on by the dryer (via Connector Box) in parallel with the in-
ternal fan.
- Off
- On
Pressure sensor
External hardware is connected via the Miele Connector Box.
When using a shared exhaust air duct, one tumble dryer may have to be switched off or
suppressed from the outset if certain pressure levels have built up in the ducting. The ex-
ternal pressure sensor is only checked if the external exhaust air flap and/or the external
additional fan is set to "on".
A message appears in the display while the exhaust air flap is open.
- Off = Not active
-
= Active
NO contact
Responds to high potential
-
= Active
NC contact
Responds to low potential
Peak load signal
External hardware is connected via the Miele Connector Box.
The peak-load negotiation function enables the tumble dryer to be connected to an energy
management system. When a signal is registered, the tumble dryer's heater is switched off
for a short period or the machine is prevented from being switched on.
A peak-load signal can be issued via the Connector Box or via the COM module.
- Factory default:
No function
36