15.18 Removing the OETIKER Clamps
The following tools are necessary to remove this component:
Pliers for Oetiker clamps (or pair of tongs)
To remove the OETIKER clamp, cut it using a pair of tongs and replace it with a
new one as shown in the figure.
Follow the instructions shown in the figure to tighten the clamp.
15.19 Dismantling of water mains inlet solenoid valve
(*only versions M2+ and B2+)
The following tools are necessary to remove this component:
Torx screwdriver T10
To access the part to be replaced, the external covers explained previously must be
disassembled until the rear panel disassembly.
Disconnect the tube as indicated in the picture
Carry out the disassembly of the pumps as explained in the section "Pump
disassembly" until the pump unit is disassembled.
Remove the 2 screws shown in figure using a Torx T10 screwdriver.
English
97