Power supply connections

SeaTalk systems

SeaTalk systems
SeaTalk systems
SeaTalk systems
SeaTalk systems
CAUTION
When instruments are connected to SeaTalk, ensure that the
power supply for the SeaTalk 12 V line is protected by a 5 A fuse.
Systems with a large number of instruments on the SeaTalk bus may
require connections to the power supply from each end of the system
('ring-main' style), to maintain sufficient voltage throughout the
system.
This requirement depends on the total length of the cable run and the
total number of instruments in the system, as follows:
Cable run
Up to 10 m
Up to 20 m
SeaTalk cable
Cable from Depth transducer
Cable from Speed transducer
Connections to ST60 Tri Data instrument
ST60 Tridata Instrument Owner's Handbook
Black
Screen
Blue
No. of instruments
13 maximum
26 maximum
7 maximum
13 maximum
SeaTalk cable
Brown
White
Screen
Green
Red
D4423-1