Leaving User Calibration; Intermediate Calibration - Raytheon ST60 Owner's Handbook Manual

Tridata instrument
Hide thumbs Also See for ST60:
Table of Contents

Advertisement

34

Leaving User calibration

Hold down the depth and speed keys for 2 seconds, to save your
settings, exit User calibration and resume normal operation.

4.3 Intermediate calibration

Intermediate calibration enables you to:
• Check the instrument software version.
• Check the instrument status - either YES (master)) or NO (repeater).
• Carry out a calibration run over a measured distance to ensure
To start Intermediate calibration, hold down the depth and speed
keys for approximately 4 seconds (see Intermediate calibration flow
chart).
To set the instrument status:
1. Press the depth key to select the Instrument status screen.
2. Press the trip and reset keys simultaneously to enter the depth
Note: You must not allocate more than one master depth instrument in
any system.
3. Press the trip and reset keys simultaneously again, to leave the
You can also change the depth status, as required. This feature is
particularly useful in preventing interference when using another
product (e.g. a fishfinder) that operates at 200 kHz.
accurate speed readings.
adjust mode, then press either trip or reset to set the required
status, i.e. either YES (for master operation) or NO (for repeater
operation).
adjust mode.
ST60 Tridata Instrument Owner's Handbook