3
Intended use
This machine has been manufactured according to the latest developments in technology and current
regulations and standards. It must only be operated in line with the instructions on correct usage.
Hazards due to improper usage!
Hazards may arise for persons, animals and material objects if the equipment is not
used correctly. No liability is accepted for any damages arising from improper usage!
•
The equipment must only be used in line with proper usage and by trained or expert staff!
•
Do not modify or convert the equipment improperly!
3.1
Applications
3.1.1
MIG/MAG standard welding
Metal arc welding using a wire electrode whereby gas from an external source surrounds the arc and the
molten pool to protect them from the atmosphere.
3.1.2
MIG/MAG cored wire welding
Welding with cored wire electrodes consisting of a metal casing and a powder core.
As with MIG/MAG standard welding, the arc is protected from the atmosphere by shielding gas. The gas
is supplied either externally (gas shielded cored wires) or produced in the arc by means of the powder
core (self-shielding cored wires).
3.1.3
MMA welding
Manual arc welding or, for short, MMA welding. It is characterised by the fact that the arc burns between
a melting electrode and the molten pool. There is no external protection; any protection against the
atmosphere comes from the electrode.
3.1.4
Air arc gouging
During air arc gouging, bad welding seams are heated with a carbon electrode and then removed with
compressed air. Special electrode holders and carbon electrodes are required for air arc gouging.
3.1.5
Voltage reducing device (VRD)
To increase safety, particularly in hazardous environments (like shipbuilding, pipe construction or mining),
the machine is equipped with the VRD (Voltage-reducing device) .
The VRD signal light is illuminated, when the voltage reducing device is operating without fault and the
output voltage is reduced to a value specified in the relevant standard (see technical data).
3.2
Use and operation solely with the following machines
A suitable wire feed unit (system component) is required in order to operate the welding
machine!
Wire feed unit
•
Taurus Basic drive 4
•
Taurus Basic drive 4L
•
Taurus Basic drive 200C
•
Taurus Basic drive 300C
Transport vehicle
•
Trolly 55.2-2
Cooling unit
•
cool50-2 U40
099-005261-EW501
11.04.2012
WARNING
NOTE
Intended use
Applications