Software and commissioning
4.2 Install example image on eMMC
8. Enter "root" after "login as" and then enter the password for "root".
You will be prompted to change the root password the first time you log in. Change the
password when prompted.
9. Now you can test some Linux commands.
4.2.3.4

Setting up network interface

The IP address on SIMATIC IOT2050's default image is set as 192.168.200.1. Therefore, if a
DHCP address or another static IP address is needed, you can configure it using the "nmtui".
Set the IP address of IOT2050
1. Open a serial Putty connection and log in as root.
2. Enter "nmtui" to open the network manager tool.
3. Navigate to the "Activate a connection" and press Enter.
4. Select the interfaces you want to enable.
– For V1.0.1, select "eth0" and "eth1"
– For V1.1.1, select "eno1" and "eno2"
Note: eth0 and eno1 are enabled by default, while eth1 and eno2 is disabled by default.
However, eth1 and eno2 are automatically enabled when a LAB cable is connected.
44
Operating Instructions, 03/2024, A5E39456816-AF
SIMATIC IOT2050