Electromagnetic Compatibility - Siemens SIMATIC IOT Operating Instructions Manual

Hide thumbs Also See for SIMATIC IOT:
Table of Contents

Advertisement

Technical specifications
9.2 Other configurations for IOT2050
For unique labeling, the LAN interfaces are numbered on the enclosure. The numbering by
1
the operating system can differ. Siemens recommends you use shielded ethernet cables.
You can use any COM port as an RS232, RS422 or RS485 interface through the software-
2
controlled interface parameter assignment.
Termination with 120 Ω terminal resistance can be set with the software.
3
The maximum cable length is 1000 m under the following preconditions:
• Data signaling rate is below 90Kbps
• Using twisted pair copper wire of 24AWG or larger diameter
Additional information on parameter assignment is available in the SIMATIC IOT2000-Forum,
see section "Software and commissioning (Page 35)".
9.2.2

Electromagnetic compatibility

Emission
Radiated emission according to IEC 61000-6-4, measuring distance 3 m
Frerangequency
30 to 230 MHz
230 to 1000 MHz
1 to 3 GHz
3 to 6 GHz
Emission of radio interference voltages according to IEC 61000-6-4
Emission port
Power port
Telecommunication / Network port
Immunity
Pulse-shaped interference
Electrostatic discharge according to IEC 61000-4-2
Bursts (high-speed transient disturbance variable)
according to IEC 61000-4-4
102
Interference emission
< 50 dB (μV/m) quasi-peak
< 57 dB (μV/m) quasi-peak
< 76 dB (μV/m) peak and < 56 dB (μV/m) average
< 80 dB (μV/m) peak and < 60 dB (μV/m) average
Interference emission
0.15 to 0.5 MHz
< 79 dB (μV) quasi peak and < 66 dB (μV) average
0.5 to 30 MHz
< 73 dB (μV) quasi peak and < 60 dB (μV) average
0.15 to 0.5 MHz
< 97 dB (μV) to 87 dB (μV) quasi peak and < 84 dB (μV) to 74 dB (μV) average
0.5 to 30 MHz
< 87 dB (μV) quasi peak and < 74 dB (μV) average
Air discharge: ± 8 kV
Contact discharge: ± 4 kV
± 2 kV supply line
± 1 kV signal line, < 30 m
± 2 kV signal line, > 30 m
Operating Instructions, 03/2024, A5E39456816-AF
SIMATIC IOT2050

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic iot2050Simatic iot2050 smSimatic iot2050 m.2

Table of Contents