Pin
7
8
10.5.6

DisplayPort 1.1A

X70
DisplayPort interface
Pin no.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
SIMATIC IOT2050
Operating Instructions, 03/2024, A5E39456816-AF
Abbreviation
Dat0
Dat1
Abbreviation
Function
Lane 0_P
Lane 0+
GND
Ground
Lane 0_N
Lane 0-
Lane 1_P
Lane 1+
GND
Ground
Lane 1_N
Lane 1-
GND
Ground
GND
Ground
CONFIG1
Connected to ground
CONFIG2
Connected to ground
AUX CH_P
Auxiliary channel+
GND
Ground
AUX CH_N
Auxiliary channel-
Hot plug
Hot Plug Detect
Return
Return for power
Connected to ground
DP_PWR
Power for connector (3.3 V 500 mA)
Function
Data line bit 0
Data line bit 1
Hardware descriptions
10.5 Internal interfaces
Input/output
Input
-
Input
Input
-
Input
-
-
-
-
Bidirectional
-
Bidirectional
output
-
power out