Power Fail LED
The Power Fail LED connection is located on Pin 5 and Pin 6 of JF1. When this LED turns
solid red, it indicates a power failure. Refer to the table below for pin definitions.
Information LED (OH/Fan Fail/PWR Fail/UID LED)
The Information LED (OH/Fan Fail/PWR Fail/UID LED) connection is located on Pin 7 and
Pin 8 of JF1. The LED on Pin 7 is active when the UID button (UID-SW) on the rear I/O panel
is pressed. The LED on Pin 8 provides warnings of overheat, power failure, or fan failure.
Refer to the table below for more information.
Information LED-Blue+ (OH/Fan Fail/PWR Fail LED/blue UID LED) (Pin 7 & Pin 8 of JF1)
Status
Solid red (on)
Blinking red (1Hz)
Blinking red (0.25Hz)
Blinking red (10Hz) (FP red LED)
Solid blue
Blinking blue (1Hz)
BIOS/BMC blinking blue (10Hz)
Red Info LED blinking (10Hz) and
MB UID LED blue blinking (10Hz)
1
Power Button
Reset Button
3.3V
Red+
(Blue LED_Cathode_UID)
NIC2 (Activity) LED
NIC1 (Activity) LED
ID_UID/3.3V Stby
3.3V
Key
NMI
19
Power Fail LED
Pin Definitions (JF1)
Pin#
Definition
5
3.3V
6
PWR Fail for LEDPWR (Solid red on: PWR failure)
LED Indicator Status
Description
An overheating has occurred.
Fan failure: check for an inoperative fan.
Power failure: check for a non-operational power supply.
CPLD recovery mode error(s)
Local UID is activated. Use this function to locate a unit in a rack mount
environment that might be in need of service.
Remote UID is on. Use this function to identify a unit from a remote location that
might be in need of service.
BIOS/BMC: recovery and/or update in progress
CPLD: recovery and/or update in progress
JF1
2
Ground
Ground
Power Fail (for LED6)
Blue+
(Red OH/Fan Fail/PWR Fail for LED5/Blue UID LED)
NIC2 (Link) LED
NIC1 (Link) LED
HDD LED
FP PWR LED
Key
Ground
20
1
70
1. Power Fail LED