1.1.4 The operation condition parameters according to GOST 15150-69 are specified in Table 3 for climatic
modification NF4
Operation conditions
Ambient air temperature
Relative air humidity
Ambient air allowable pressure
Transportation temperature
range
Storage temperature range
Structural design category
Altitude above sea level
Environment
Installation site
Operating position

1.2 Specifications

Key parameters of the turnstile are specified in Table 4.
Maximum lane width
Traffic flow capacity in free access mode, at least
Opening/closing time
Power supply voltage:
– AC power supply (primary)
– DC power supply (secondary)
Maximum power consumption
Index of protection according to EN 60529
Mechanism
Locking system
In case of power failure
LED Light:
- display showing access status
- card reader area
- glass leaf showing turnstile
Reliability indices
Mean time to repair (without delivery time of spare parts, tools and
accessories)
Mean time to failure
Mean service life between overhauls

1.3 Configuration and Scope of Delivery

1.3.1 The turnstile design depends on the number of passageways:
1) For arrangement of single access way the turnstile "Speedblade-BM 900-1" is a set of two similar cabinets
(Master and Slave), each of which has one glass leaf (reference designation Т3.КСD.ХV);
2) For arrangement of two or more passageways the turnstile is a set of two single sides cabinets "Speedblade-BM
900-1" (reference designation Т3.КСD.ХV) and one or more additional cabinets "Speedblade-BM 900-2" with two sides
leaves (reference designation Т3.КСD.ХV.Х).
explosion-proof, does not contain current-conducting dust, aggressive gases and
vapours in concentration destroying isolation and metals, disturbing normal
operation of the equipment installed in turnstiles
in enclosed spaces in the absence of direct impact of precipitations and solar
radiation
vertical, deviation from vertical position no more than 1º to any side is allowed
Parameter description
Table 3 - The operation condition parameters
Parameter value
+1°С to +40°С
80% at +20ºС (non-condensing)
84 to 106,7 kPa
- 40°С to + 50°С
+ 5 to + 40°С
L3
up to 2000m
Table 4- Key parameters of the turnstile
MВDrive
(gates can be opened manually)
– at least 10 000 000 accesses
Operation Manual 7
Parameter value
900 mm
25 person/min.
0,8 s
100  240 V ~ 50/60 Hz
12 V
160 W
IP41-54*
servo-driven (BLDC)
DeadLock
Fail-safe
DotLights®
RFIDLights®
LeafLights®
– at most 6 hours;
– at least 10 years