Page 1
«TiSO-PRODUCTION» LTD WAIST-HIGH TURNSTILES SPEEDBLADE-BM 900 of retractable lane of Speed Gate series OPERATION AND INSTALLATION MANUAL 2023 AUIA.177-07 rev.1.1 UKRAINE...
5 TRANSPORTATION AND STORAGE ........................31 6 DISPOSAL ..................................31 Annex А. Overall and installation dimensions of the set of turnstile "SpeedBlade-BM 900" (with different top and access way width) ............................... 32 Annex B. Control panel and connection diagram ......................33 Annex C.1.
So, fulfillment of all requirements specified in this document is mandatory. The turnstile “SpeedBlade-BM 900" can be installed either singly or in line. the single turnstile includes two cabinets (left-hand and right-hand), each of which has one telescopic glass leaf.
Operation Manual 4 WARNINGS TO THE CUSTOMER ON SAFE OPERATION OF THE TURNSTILE These warnings are designed for ensuring of safety during operation of the turnstile to prevent violation of safety characteristics by improper installation or operation. These warnings are aimed at drawing attention of the customer to safety problems.
(from magnetic card readers) or manually (from manual control panel). Speedblade-BM 900 – motorized turnstile featured with safe and retractable tempered glass leaves. Telescopic mechanism allows keeping standard cabinet’s instead of making it twice bigger, as commonly known solution to arrange passage for people with special needs (900 mm).
Page 6
Length weight, kg One side cabinet “SpeedBlade-BM 900 -1.2” Slave АUІА.177-07.1 Т3.КСD.XV 1000 “SpeedBlade-BM 900 -1.1” Master AUІА.177-07.1 /1000* /295* /1005* Double side cabinet Т3.КСD.XV.X “SpeedBlade-BM 900 -2” Master/Slave АUІА.177-07.2 * Overall dimension for the turnstile with solid tempered glass top is 5mm more (than with stainless steel tops with...
1.3.1 The turnstile design depends on the number of passageways: 1) For arrangement of single access way the turnstile “Speedblade-BM 900-1” is a set of two similar cabinets (Master and Slave), each of which has one glass leaf (reference designation Т3.КСD.ХV);...
Page 8
1.3.3 Design of the turnstile of “Speedblade-BM 900-2” The turnstile is an additional cabinet “SPEEDBLADE-BM 900 -2” (Master/Slave) with two leaves (glass panels). The number of additional cabinets is specified in order. The turnstile «SPEEDBLADE -2» operates only as part of the turnstile “SPEEDBLADE-BM 900 -1”...
5 – top lid (solid glass top or stainless steel top with plastics inserts); 6 – front panel; 7 – turnstile base; 8 – BMDrive® gear motor ; 9 –side panel (front and back) Fig. 4 – Design of the single turnstile of Т3.КСD.ХV. “Speedblade-BM 900-1” type...
Page 10
17 - circuit breaker; 18 - power supply unit ; 19 - link board for Master and Slave; 20 - main controller AUIA.206.21.00.00; 21 - motor controller AUIA.401.00.00-01 Fig. 5– General appearance and design of “SpeedBlade-BM 900-2” turnstile mechanism (Master cabinet)
Page 11
Operation Manual 11 1.4.3 Principle of operation 1) Turnstile status indication - LED Light of card reader area; - LED lighting display showing access status; LED lighting of leaves showing access status; Fig.6 – Light indication of the turnstile status 2) Access cycle: Standby mode 1.
Operation Manual 12 1.5 Description and operation of controllers as integral component of the turnstile 1.5.1 Main controller AUIA.206.21.20.00 1.5.1.1 Description of operation The controller provides algorithm of operation of the whole turnstile. It is assembled on the 120 х 80 mm size card from foil-clad textile laminate, on which electronic components and terminals for connection to other turnstile units as well as for connection to control peripherals (ACS, control panel etc.) are located.
Page 13
Operation Manual 13 "LOCK OF ACCESS" The turnstile switches to this mode only upon command "LOCK OF ACCESS А/В" arrived via interface RS-485 from control panel. Thus red LED is blinking from the side of locked access, glass leaves are closed (if the turnstile is not open for free or single access from opposite side), controller does not respond to signals of inputs "INP1"...
Page 14
Operation Manual 14 The purpose of the controller contacts intended for connection to peripherals is specified in Table 6. Table 6- The purpose of the controller contacts AUIA.206.21.20.00 № Directio Signal description and Description Designation Connector parameters /contact 1) logical «0» (02,2) V; INP1 ХТ4/1 Command "TO BE OPENED...
Operation Manual 15 1.5.2 Motor controller АUIA.401.00.00-01 1.5.2.1. Description of motor controller АUIA.401.00.00-01 ® The controller АUIA.401.00.00-01 is designed to control BMDrive gear motors, which drives the turnstile leaves in motion. At each passage of turnstile installed pair of controllers АUIA.401.00.00-01: the first controller drive the leaf in the Master cabinet, the second controller drive leaf in the Slave cabinet.
Page 16
Operation Manual 16 1.5.2.2. Description of the main page of the controller An OLED display and 4 control buttons are installed on the front side of the AUIA.401.00.00-01 controller for the displaying the current state of the controller and for configuration settings at menu After initialization of the controller the main page of the menu is displayed on the screen.
Page 17
№ Direction Designation Description Connector/contact XT1/1 EXIT Common wire of the control panel (GND ) XT1/2 DATA RS485 (1) communication line with 7-button TISO control panel XT1/3 DATA XT1/4 EXIT Power output for control panel (+12V) XT1/5 +12V EXIT Power output (+12V) for additional devices...
Page 18
Operation Manual 18 Continued table 7 XP6/1 RS - A DATA RS 485 (2) communication line with the leaf position sensor XP6/2 RS - B DATA Сommon XP6/3 EXIT XP6/4 +12V EXIT Power supply of leaf position sensor XP8/1 ENTRY Jumper of line RS 485 (2) pull up resistor XP8/2 ENTRY...
Operation Manual 19 2 INTENDED USE 2.1 Operation restrictions 2.1.1The turnstile must be used in the environment specified in p. 1.1.4 of this document subject to the specifications listed in section 1.2. 2.1.2 It is forbidden to use the turnstile: –...
Page 20
Operation Manual 20 2.2.5 General layout of the “Speedblade-BM 900” turnstile passage ways Fig. 14 – “Speedblade-BM 900” type turnstile layout options...
Figure 16. The turnstile itself, located upright at the installation site, can be used as a template • The relevant holes to be drilled on the surface according to the marking due to diameter of anchors (12×120М10) for the turnstile fixation. Fig. 16 – Installation dimensions of the “Speedblade-BM 900” turnstile...
Page 22
Operation Manual 22 IMPORTANT! Cabinets are linked by control line optical sensor system requiring accurate positioning of cabinets. The relative position of cabinets and vertical position of the turnstile to be respected. Cable entry must be carried out in corrugated or metal pipes. The lengths of the free ends of the cables must be at least 1 m to provide input, cut and connect them to the corresponding terminals in the turnstile frame.
Page 23
Operation Manual 23 Option 1 Option 2 Fig. 18 – Options of cable connection between cabinets Master and Slave of “Speedblade-BM 900”...
Page 24
Operation Manual 24 5) General assembly and installation of cabinet of “SpeedBlade-BM 900” turnstile To provide access to fixation holes and terminal blocks from both sides of cabinet it is required to: 1.– remove the turnstile lid by unscrewing screws on the ends (See Fig. 19);...
Page 25
After the necessary installation, install the doors and side panels (Fig. 19) on their attachment points, fix the top lid Fig.22 – Installation of proximity card reader with screws. Fig. 23 – Maximum dimensions of identification card reader installed in turnstile “SpeedBlade-BM 900”...
If necessary, before the turnstile initialization for the first time, adjust the bracket with the magnetic sensor board. The procedure for “Speedblade-BM 900” turnstile leaf initialization procedure and adjustment of the magnetic sensor board is specified in paragraph 4.3 of this Operation Manual.
Operation Manual 27 Continuation of table 8 "FREE" button Glass leaves are pushed inside Green arrow pushed access the turnstile opening access in 8. Free access in one authorized free access in chosen direction (“A” or the intended direction direction and locked chosen direction is lit “B”) and "LOCK"...
Operation Manual 28 3 MAINTENANCE 3.1 General guidelines 3.1.1 Commissioning and subsequent maintenance of the turnstile to be performed only by the staff being in charge of the turnstile. 3.1.2 The turnstile to be serviced only by the staff having the relevant electrical safety qualification level according to the national requirements.
Operation Manual 29 4 ROUTINE MAINTENANCE 4.1 General guidelines IMPORTANT: INSPECTION, CLEANING, REPAIR OF THE TURNSTILE COMPONENTS TO BE PERFORMED ONLY AFTER THE TURNSTILE IS DEENERGIZED ! 4.2 Possible malfunctions Possible malfunctions of the turnstile and their remedies are listed in Table 10. Table 10 - Possible malfunctions Malfunction Possible cause...
4.3. “Speedblade-BM 900” turnstile leaf initialization procedure For “SpeedBlade-BM 900” turnstiles, the zero position can be at point CLOSE (0). For turnstiles of this type, the zero position is determined and set automatically during working area searching. ...
Operation Manual 31 Option ІІ (with АUIA.401.00.00-01 fig.25) Run the menu holding for 2 seconds the lower button controller АUIA.401.00.00-01 choose “Calibration”->”GateZeroSet” controller. If you request a calibration procedure, the turnstile will go to “OFF” mode. Confirm the start of working area search procedure by pressing “YES”...
Annex B. Control panel and connection diagram 1 – control panel body; 5 – "FREE ACCESS" mode control button 2 – "SINGLE ACCESS" mode control button 6 – "PANIC" mode control button 3 – front plate; 7 – access direction LED display; 4 –...
Annex C.1. Wiring diagram of SpeedBlade-BM 900 1.1 BLDC Master (AUIA. 177-07) Rev 0.7 MINI-FIT 8 Z5BLD120-24GUL ПВ3 0 .7 5 (Gre e n ) MOT B (V) Hall C (W) ПВ3 0 .7 5 (Ye l l o w ) MOT A (U) ПВ3 0 .7 5 (Bl u e )
Annex C.2. Wiring diagram of SpeedBlade-BM 900 1.2 BLDC Slave (AUIA. 177-07) Rev 0.7 A A2 P CB .205.01.05.00 X S 25 X P 1 M INI-FIT 8 +12V Z5BLD120-24GUL P CB 715.001 ПВ3 0 .7 5 (G re e n )
Annex C.3. Wiring diagram of SpeedBlade-BM 900 2 BLDC Master/Slave (AUIA. 177-07) Rev 0.7 AA 1 M I N I - FI T 8 Z5 BL D1 2 0 -2 4 GUL П В3 0. 75 ( G r een)
Annex D.1 Diagram of the turnstile connection to access control system (ACS) Relay 1 Relay 2 Door contact 1 Door contact 2 inp1 - "TO BE OPENED A" in pulse mode. When command is issued entry is activated for 5 sec. inp2- "TO BE OPENED B"...
Annex D.2 Diagram of the turnstile connection to access control system (ACS) inp1- " TO BE OPENED A" in pulse mode. When command is issued the input is activated for 5 sec. . inp - 2 " TO BE OPENED B" in pulse mode. When command is issued the input is activated for 5 seconds.
Annex D.3 Diagram of the turnstile connection to fire alarm (FA) inp1- " TO BE OPENED A" in pulse mode. When command is issued the input is activated for 5 sec. inp - 2 " TO BE OPENED B" in pulse mode. When command is issued the input is activated for 5 seconds.
Annex D.4 Diagram of the turnstile connection to control panel 5 4 3 2 1...
Page 41
MANUFACTURER SERVICE CENTER 14 Promyslova str., 02088 Kyiv , Ukraine "TISO-PRODUCTION" LLC 14 Promyslova str., 02088 Kyiv, Ukraine +380 (44) 291-21-11 +380 (44) 291-21-11 service1@tiso.global www.tiso.global sales@tiso.global Our equipment complies with requirements of the European Standards: EN ISO 12100:2010, EN 614-1:2006+А1:2009, EN 1037:1995+А1:2008, EN 60204-1:2006, EN 953:1997+А1:2009, ISO 3864:1995, EN ISO 13857:2008, EN ISO 13849-1:2006,...
Need help?
Do you have a question about the SPEEDBLADE-BM 900 and is the answer not in the manual?
Questions and answers