Table 20. 460-Volt UL Type-1/IP-20 Chassis Standard Ratings Table.
Output Current
Model
100/115% Cont.
Number
(110% Cont.
≥ 125 HP)
ACEG94001
2.7/3.1 A
ACEG94002
3.6/4.1 A
ACEG94003
5.0/5.8 A
ACEG94005
9.1/10.5 A
ACEG94007
12.4/14.3 A
ACEG94010
15.3/17.6 A
ACEG94015
24.0/27.6 A
ACEG94020
28.6/32.9 A
ACEG94025
35.7/41.1 A
ACEG94030
42.0/48.3 A
ACEG94040
57.2/65.8 A
ACEG94050
68.5/78.8 A
ACEG94060
81.5/93.7 A
ACEG94075
100.8/115.9 A
ACEG94100
138.7/159.5 A
ACEG94120
179/196.9 A
ACEG94150
215/236.5 A
ACEG94200
259/284.9 A
ACEG94250
314/345.4 A
ACEG94300
387/425.7 A
ACEG94350
427/469.7 A
ACE-tronics G9 ASD Installation and Operation Manual
Overload Current
Overload Current
150% for 60
150% for 120
Seconds
Seconds
4.1 A
5.4 A
7.5 A
13.7 A
18.6 A
23.0 A
36.0 A
N/A
42.9 A
53.6 A
63.0 A
85.8 A
102.8 A
122.3 A
151.2 A
208.1 A
268.5 A
322.5 A
388.5 A
N/A
471.0 A
580.5 A
640.5 A
Input Voltage
Output Voltage
3-Ph 50/60
3-Ph Variable
±2 Hz
Frequency
380 – 480 VAC
Input Voltage
(±10%)
Level (Max.)
Typical
Motor HP
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
350
271