efesotomasyon.com -Toshiba inverter,drive,servo,plc
F965
Monitor Output Function 11
Program  My Function  My Function Monitor
This parameter plays a role in the setup of the My Function feature by
establishing the function that is to be recorded and output as the Peak,
Minimum, or Normal (Avg.) value as selected at parameter Proportional.
Select the Monitor Display Input Setting number from
output the corresponding function.
Use the Communication Number if operating using communications.
Monitor Output Function Command 11
Program  My Function  My Function Monitor
This parameter plays a role in the setup of the My Function feature by allowing
the user to select the Peak, Minimum, or Normal (Avg.) value of the
parameter
F965
selection to be recorded and output as a monitored function.
Settings:
Normal
Peak
Minimum
Monitor Output Function 21
Program  My Function  My Function Monitor
This parameter plays a role in the setup of the My Function feature by
establishing the function that is to be recorded and output as the Peak,
Minimum, or Normal (Avg.) value as selected at parameter F968.
Select the Monitor Display Input Setting number from
output the corresponding function.
Use the Communication Number if operating using communications.
Monitor Output Function Command 21
Program  My Function  My Function Monitor
This parameter plays a role in the setup of the My Function feature by allowing
the user to select the Peak, Minimum, or Normal (Avg.) value of the
parameter
F967
selection to be recorded and output as a monitored function.
Settings:
Normal
Peak
Minimum
224
Direct Access Number — F965
Parameter Type — Selection List
Factory Default — 2000
Changeable During Run — Yes
Table 12 on pg. 245
to
Direct Access Number — F966
Parameter Type — Selection List
Factory Default — Normal
Changeable During Run — Yes
Direct Access Number — F967
Parameter Type — Selection List
Factory Default — 2000
Changeable During Run — Yes
Table 12 on pg. 245
to
Direct Access Number — F968
Parameter Type — Selection List
Factory Default — Normal
Changeable During Run — Yes