Toshiba G9 Installation And Operation Manual page 218

Table of Contents

Advertisement

efesotomasyon.com -Toshiba inverter,drive,servo,plc
F870
Block Write Data 1
Program  Communications  Communication
This parameter plays a role in the setup of the communications network by
establishing the type of data to be written to the ASD of the communications
link.
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (off then on)
for the changes to take effect.
Settings:
None
FA00 (Command 1)
FA20 (Command 2)
FA01 (Frequency)
FA50 (TB Output)
FA51 (Analog Output)
Block Write Data 2
Program  Communications  Communication
This parameter plays a role in the setup of the communications network by
establishing the type of data to be written to the ASD of the communications
link.
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (off then on)
for the changes to take effect.
Settings:
None
FA00 (Command 1)
FA20 (Command 2)
FA01 (Frequency)
FA50 (TB Output)
FA51 (Analog Output)
208
Direct Access Number — F870
Parameter Type — Selection List
Factory Default — None
Changeable During Run — Yes
Direct Access Number — F871
Parameter Type — Selection List
Factory Default — None
Changeable During Run — Yes
ACE-tronics G9 ASD Installation and Operation Manual
F871