efesotomasyon.com -Toshiba inverter,drive,servo,plc
F352
Deceleration Suspend Frequency
Program  Fundamental  Acc/Dec 1
When Enabled at F349, this parameter is used to set the frequency at which the
Deceleration Suspend function will activate.
During deceleration, this parameter sets the frequency at which deceleration
will stop and the motor will run at the setting of this parameter for the time
setting of F353.
Deceleration Suspend Time
Program  Fundamental  Acc/Dec 1
When Enabled at F349, this parameter is used to set the duration of activation
of the Deceleration Suspend function when initiated by reaching the
Deceleration Suspend Frequency setting (F352).
Once this parameter times out the deceleration rate will resume from the point
of suspension.
148
Direct Access Number — F352
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — Max. Freq. (F011)
Units — Hz
Direct Access Number — F353
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 10.0
Units — Seconds