Functional descriptions and schematics
High pressure
Return flow
Active
Sensor input
(no buttons pressed)
Control unit input
(buttons pressed)
www.zepro.com
Z 1500/2000 MA with digital auto tilt
Function: close
Description:
Closing fully against the box body.
Control input: Tilt + Up + 2H button on primary control device(s).
Sensor input: None required for function.
Card indication
ZePRO1
Di2
Di1
Di3
Di6
Di4
(flashing)
Di5
In
Up (B)
Tilt (C)
Down (E)
2H/X
Out
(flashing)
Must be active for the function to be executed.
Must be inactive for the function to be executed.
May be active or inactive, the function will be executed either way.
TLC-B1