Zepro Z 1500 Technical Manual page 40

Hide thumbs Also See for Z 1500:
Table of Contents

Advertisement

Functional descriptions and schematics
High pressure
Return flow
Active
Sensor input
(no buttons pressed)
Control unit input
(buttons pressed)
40
Z 1500/2000 MA with digital auto tilt
Function: auto tilt down
Description:
Automatic down tilting of the platform once ground level has been reached.
Control input: Down. Available on all control devices.
Sensor input: Active pressure sensor on lift cylinder.
ZePRO1
Di2
Di1
Di6
Di4
Di5
In
Up (B)
Down (E)
2H/X
Out
Must be active for the function to be executed.
Must be inactive for the function to be executed.
May be active or inactive, the function will be executed either way.
Card indication
TLC-B1
Output status LED's
U0
Di3
U1
U2
U3
U4
U5
(flashing)
U6
U7
WL
PWR
Tilt (C)
Input fuse
(flashing)
Output fuse
Input status LED's
UP
DOWN
TILT
2H
IN
OUT
S5(+S1)
S4
S3
S2
www.zepro.com