Functional descriptions and schematics
High pressure
Return flow
Active
Sensor input
(no buttons pressed)
Control unit input
(buttons pressed)
www.zepro.com
Z 1500/2000 MA with digital auto tilt
Function: manual tilt down
Description:
Tilting down within +45/-10 degrees from horizontal.
Control input: Tilt + Down + 2H button on all control devices.
Sensor input: Active angle sensor on platform.
ZePRO1
Di2
Di1
Di3
Di6
Di4
(flashing)
Di5
In
Up (B)
Tilt (C)
Down (E)
2H/X
Out
(flashing)
Must be active for the function to be executed.
Must be inactive for the function to be executed.
May be active or inactive, the function will be executed either way.
Card indication
TLC-B1
Output status LED's
U0
Output fuse
U1
U2
U3
U4
U5
Input status LED's
U6
U7
WL
PWR
Input fuse
UP
DOWN
TILT
2H
IN
OUT
S5(+S1)
S4
S3
S2
41