Functional descriptions and schematics
High pressure
Return flow
Active
(no buttons pressed)
Control unit input
(buttons pressed)
42
Z 1500/2000 MA with digital auto tilt
Function: auto tilt up
Description:
Automatic up tilting of the platform untill it is tilted back to horizontal.
Control input: Up. Available on all control devices.
Sensor input: Active IFM type angle sensor on platform.
Di2
Di1
Sensor input
Di6
Di5
In
Up (B)
Down (E)
Out
Must be active for the function to be executed.
Must be inactive for the function to be executed.
May be active or inactive, the function will be executed either way.
Card indication
ZePRO1
TLC-B1
Output status LED's
U0
Di3
U1
U2
U3
Di4
U4
U5
(flashing)
U6
U7
WL
PWR
Tilt (C)
2H/X
Input fuse
(flashing)
Output fuse
Input status LED's
UP
DOWN
TILT
2H
IN
OUT
S5(+S1)
S4
S3
S2