Functional descriptions and schematics
High pressure
Return flow
Active
www.zepro.com
Z 1500/2000 MA (ZDK 250)
Function: lower
Description:
Vertical platform lowering.
Control input: Down. Available on all control devices.
Sensor input: None required for function.
Card indication
Must be active for the function to be executed.
Must be inactive for the function to be executed
May be active or inactive, the function will be executed either way.
TLC-B1
Output status LED's
U0
Output fuse
U1
U2
U3
U4
U5
Input status LED's
U6
U7
UP
WL
DOWN
PWR
TILT
2H
IN
OUT
S5(+S1)
S4
S3
Input fuse
S2
29