4. From the Patterns Send screen, press F1 to send a
511 pattern, F2 to send a 1-in-8 pattern, or F3 to
send a QRSS pattern.
Patterns: Send
511
F1
If you send a 1-in-8 pattern, skip Step 5.
5. From the Send screen, press the Function key that
corresponds to the port for which you want to send
a test pattern. Use the scroll keys, if necessary.
Send: Name
Prt1
F1
511 (Port)
1 in 8 (Network)
QRSS (Port)
3170-A2-GB20-10
1in8
QRSS
F2
F3
Prt2
Prt3
F2
F3
Table 4-9
Valid Send Test Pattern Combinations
511 (Port)
YES (on
separate ports)
NO
YES (on
separate ports)
March 1996
The Test Started screen appears.
Send: Name and Dest
Test Started
F1
If the E1 DSU/CSU is already sending the test
pattern you selected, the message Already active
appears. If you selected an incompatible test
pattern combination, the message Invld Test
Combo appears. See Table 4-9 for valid
combinations.
1-in-8 (Network)
NO
N/A
NO
Maintenance
F2
F3
QRSS (Port)
YES (on
separate ports)
NO
YES (on
separate ports)
4-21