To change the customer identification (CID),
1. Press the
key on the top-level menu to bring
the Ctrl branch onto the front panel LCD.
DSU E1 CEPT
Stat
F1
2. Press F3 to select Ctrl from the top-level menu
screen.
DSU E1 CEPT
Test
F1
3. Press the
key on the Control screen until the
CID selection appears on the front panel LCD.
Control:
Rel
F1
3170-A2-GB20-10
Test
Cnfig
F2
F3
Cnfig
Ctrl
F3
F2
LED
ClrReg
F3
F2
March 1996
4. Select CID.
Control:
Reset
CID
F1
F2
5. Use the
and
keys to position the cursor
under the desired character. You must enter a
moves the cursor to the
character before the
next space to the right.
CustID:xxxxxxxx
Up
Down
F1
F2
6. Enter the desired ID. Press F1 (Up) and F2
(Down) to scroll up and down through the valid
characters/numbers for the customer ID. Valid
characters are 0 through 9, #, -, ., /, A to Z, and
blank space. Press F3 (Save) to save the ID.
CustID:xxxxxxxx
Up
Down
F1
F2
Operation
DL
F3
Save
F3
Save
F3
3-9