Num Trap Mgrs: 1
Next
1
2
3
4
5
Number of Trap Managers. Specifies the number of SNMP trap managers that are to receive traps for this unit.
NOTE: You must configure an IP address for each trap manager that is to receive trap messages.
Trap n IP Adr: Clear
Next
Edit
Clear
Prev
Trap n IP Address. Specifies the IP address for each trap manager. This configuration option is repeated for all trap
managers supported by the unit.
Edit – Allows you to edit or display the IP address for Trap Manager n .
Clear – Allows you to clear the IP address for Trap Manager n .
Trap n Dst: None
Next
None
Com
Aux
Trap Manager n Destination. Specifies the network destination for Trap Manager n . This configuration option is displayed
for the number of trap managers ( n ) specified by the Number of Trap Managers configuration option.
None – No Trap Manage n network destination. Traps are discarded.
Com – The Trap Manager n network destination is the communication port. This selection only appears if the Com Use
configuration option is set to SNMP or Daisy.
Aux – The Trap Manager n network destination is the auxiliary port. This selection only appears if the Aux Use
configuration option is set to SNMP or Daisy.
FDL – The Trap Manager n network destination is the FDL management link. This selection only appears if the FDL
management link is enabled for SNMP.
EDL n – The Trap Manager n network destination is the EDL n port (where n is 1– 4). This selection only appears if the
synchronous data port's EDL management link is enabled for SNMP.
NOTE: If the chosen destination link is disabled or down, the traps are discarded. Change the trap destination if the link
ceases to be operational.
Gen Trap: Both
Next
Disab
Warm
Auth
General Trap Types. Specifies the general trap types to enable. For more information, refer to the SNMP Traps section in
Chapter 4, Maintenance .
Disab – Disables the sending of trap messages for warmStart and authenticationFailure events.
Warm – Sends trap messages for warmStart events to the currently configured trap manager(s).
Auth – Sends trap messages for authenticationFailure events to the currently configured trap manager(s).
Both – Sends trap messages for warmStart and authenticationFailure events to the currently configured trap manager(s).
NOTE: This configuration option is not available and does not appear if the SNMP Trap configuration option (in the
Alarm Configuration Options section) is disabled.
3170-A2-GB20-10
Table C-10
(1 of 2)
SNMP Trap Configuration Options
6
Prev
FDL
EDL1
EDL2
EDL3
Both
Prev
March 1996
EDL4
Prev
Configuration Options
C-21