7. Select the desired port by pressing its
corresponding Function key.
Channel Config:
Prt1
F1
8. The configuration option for the data port channel
allocation destination appears on the screen. Select
NET to assign this port to the Network E1
interface, select DTE to assign this port to the
DTE Drop/Insert interface, or press the
and the appropriate Function key to assign this
port to another port.
Assign To:NET
Next
F1
9. Press F1 (Next) to display the appropriate
configuration options on the screen. Use one of
the following examples, depending on whether
you are assigning by block or individual channel.
Block Channel Assignment Method
The Assign By configuration option screen appears
after you select a port.
To assign by the block method,
1. Press F2 (Block).
Assign By:
Next
F1
3170-A2-GB20-10
Prt2
Prt3
F2
F3
key
NET
DTE
F2
F3
Block
Chan
F3
F2
March 1996
2. Press F1 (Next) to display the next configuration
option (Port Rate).
Assign By:Block
Next
Block
F1
F2
3. Use the
or
key to scroll the desired port
rate onto the screen. Rates scroll in groups of
three. Available selections depend on the current
base rate selected for the port. Press the
corresponding Function key to select the port rate.
Then, select Next to display the Start At
configuration option on the screen.
Port Rate:384
Next
64
F1
F2
4. The Start At screen displays the configuration
option used to select the starting DS0 channel. If
the destination selected is the Network E1
interface, then the Network channels appear on the
screen. If the destination selected is the DTE
Drop/Insert interface, then these channels appear
on the screen.
The following screen shows an example of the
Network E1 interface. Use the
scroll the desired channel onto the screen. Use the
Function keys to select the starting channel. Only
those DS0 channel numbers that provide enough
bandwidth (based on the configured data rate) to
be used as a starting channel number are
displayed. Channel allocation for this port can
only be cleared by selecting Clear.
Start At:Clear
Next
Clear
F1
F2
Operation
Chan
F3
128
F3
or
key to
N1
F3
3-29