ACCULINK 317x E1 DSU/CSU
Output Signal Table – "rs232OutSigChanges"
(rs232OutSigEntry 4)
This object is not supported by the E1 DSU/CSU.
Generic-Interface Extension
MIB (RFC 1229)
The generic-interface MIB is an experimental MIB that
provides extensions to the generic interface group defined
in MIB II. This MIB describes three tables:
Generic Interface Extension Table
Generic Interface Test Table
Generic Receive Address Table
Only the generic interface test table is supported by the
E1 DSU/CSU. This table is supported for the network
interface only.
Generic Interface Test Table, Generic
Interface MIB
The test table provides access to additional tests
(loopbacks and pattern tests) that are not in the interface
group of MIB II.
Generic Interface Test Table – "ifExtnsTestType"
Object (ifExtnsTestEntry 4)
This object is a control variable used to start and stop
operator-initiated tests on the interface. It provides the
capability to:
Start/stop the Send 1-in-8 test pattern on the
network interface.
Start/stop the Send QRSS/511 test pattern on a
synchronous data port.
Start sending a V.54 UP/DOWN code to the remote
unit for a synchronous data port.
Start/stop the Monitor QRSS/511 test pattern on a
synchronous data port.
Start/stop the DCLB/DTLB loopback test on a
synchronous data port.
E-14
The following object identifiers control tests on the
interface.
noTest – Stops the test in progress on the interface.
testFullDuplexLoopBack – Initiates a DCLB on the
interface. Only supported for the data ports.
testLoopDTLB – Initiates a DTLB on the interface.
Only supported for the data ports.
testMonQRSS – Initiates a Monitor QRSS test on
the interface. Only supported for the data ports.
testMon511 – Initiates a Monitor 511 test on the
interface. Only supported for the data ports.
testSendQRSS – Initiates a Send QRSS test on the
interface. Only supported for the data ports.
testSend511 – Initiates a Send 511 test on the
interface. Only supported for the data ports.
testSendV54Up – Sends a V54 Up code to the
remote unit. Only supported for the data ports.
testSendV54Down – Sends a V54 Down code to
the remote unit. Only supported for the data ports.
testSend1in8 – Initiates a Send 1-in-8 test on the
network interface.
Where these object identifiers are defined as follows:
noTest – OBJECT IDENTIFIER ::=
[wellKnownTests 0]
testFullDuplexLoopBack – OBJECT
IDENTIFIER ::= [wellKnownTests 1]
testLoopDTLB – OBJECT IDENTIFIER ::=
[wellKnownTests 2]
testMonQRSS – OBJECT IDENTIFIER ::=
[wellKnownTests 3]
testMon511 – OBJECT IDENTIFIER ::=
[wellKnownTests 4]
testSendQRSS – OBJECT IDENTIFIER ::=
[wellKnownTests 5]
testSend511 – OBJECT IDENTIFIER ::=
[wellKnownTests 6]
March 1996