A.3 Operating Temperature Limitations
Table A-6 Operating temperature limitations
Configuration
24 x 3.5" drive switch
model configuration
20 x 2.5" drive switch
model configuration
24 x 3.5" drive pass-
through model
configuration
Issue 02 (2023-12-13)
Maximum Operating
Temperature: 30ºC
(86ºF)
When the number of front
drives is less than or
equal to 12, A40 GPUs
are supported.
All configurations are
supported.
When the number of front
drives is less than or
equal to 12, A40 GPUs
are supported.
Copyright © xFusion Digital Technologies Co., Ltd.
A Appendix
Maximum Operating
Temperature: 35ºC
(95ºF)
● When the CPU power
is higher than 270 W
and the number of
front drives is less
than or equal to 12,
A100/H100 GPUs are
supported.
● When the CPU power
is 270 W or lower than
270 W and the number
of front drives is less
than or equal to 16,
A100/H100 GPUs are
supported.
● A40 GPUs are not
supported.
● A40 GPUs are not
supported.
● When the CPU power
is higher than 270 W
and the number of
front drives is less
than or equal to 12,
A100/H100 GPUs are
supported.
● When the CPU power
is 270 W or lower than
270 W and the number
of front drives is less
than or equal to 16,
A100/H100 GPUs are
supported.
● A40 GPUs are not
supported.