5.5.1.2 20 x 2.5" Drive Configuration

Drive Configuration
Table 5-10 Drive configuration
Configuration
20 x 2.5" drive switch model
configuration
● a: The PCIe plug-in RAID controller card is installed in slot 26 by default.
● Consult your local sales representative or see "Search Parts" in the
Drive Numbering
The drive numbers identified by the RAID controller card vary depending on the
cabling of the RAID controller card. This section uses the drive numbers identified by
a RAID controller card that adopts the default cabling described in "Internal Cabling"
in the FusionServer G5500 V7 Server Maintenance and Service Guide.
Drive numbering of the 20 x 2.5" drive (8 x SAS/SATA + 12 X NVMe) configuration in
Table 5-10
Figure 5-16 Drive numbering
Issue 02 (2023-12-13)
Front Drive
● Front drives: 20 x 2.5"
– Slots 0 to 3 and 12 to 15
support only SAS/SATA
drives.
– Slots 4 to 11 and slots 16
to 19 support only NVMe
drives.
NO TICE
Copyright © xFusion Digital Technologies Co., Ltd.
5 Hardware Description
Drive Management Mode
● SAS/SATA drive: 1 x RAID
a
controller card
● NVMe drive:
– CPU pass-through
– PCIe switch
Compatibility