xFusion Digital Technologies FusionServer G5500 V7 Technology White Paper

xFusion Digital Technologies FusionServer G5500 V7 Technology White Paper

Advertisement

Quick Links

FusionServer G5500 V7 Server
Technical White Paper
Issue
02
Date
2023-12-13
xFusion Digital Technologies Co., Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FusionServer G5500 V7 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for xFusion Digital Technologies FusionServer G5500 V7

  • Page 1 FusionServer G5500 V7 Server Technical White Paper Issue Date 2023-12-13 xFusion Digital Technologies Co., Ltd.
  • Page 2 Notice In this document, "xFusion" is used to refer to "xFusion Digital Technologies Co., Ltd." for concise description and easy understanding, which does not mean that "xFusion" may have any other meaning. Any "xFusion" mentioned or described hereof may not be understood as any meaning other than "xFusion Digital Technologies Co., Ltd.", and xFusion Digital Technologies Co., Ltd.
  • Page 3: About This Document

    About This Document Overview This document describes the appearance, features, performance parameters, and hardware and software compatibility of FusionServer G5500 V7, so that users can have an in-depth and detailed understanding of FusionServer G5500 V7. Intended Audience This document is intended for presales engineers.
  • Page 4 Technical White Paper About This Document Change History Issue Date Description 2023-12-13 ● Added 11 Waste Product Recycling. ● Updated Certifications. ● Updated Nameplate. 2023-10-09 This issue is the first official release. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 5: Table Of Contents

    5.5.1 Drive Configuration and Drive Numbering....................30 5.5.1.1 24 x 3.5" Drive Configuration....................... 31 5.5.1.2 20 x 2.5" Drive Configuration....................... 35 5.5.2 Drive Indicators............................37 5.5.3 RAID Controller Card..........................39 5.6 Network..............................39 5.6.1 OCP 3.0 NICs............................39 Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 6 A.1.2 Chassis Internal Label..........................84 A.1.3 Chassis Tail Label...........................85 A.2 SN................................85 A.3 Operating Temperature Limitations......................87 A.4 Nameplate..............................88 A.5 RAS Features............................88 A.6 Sensor List..............................88 A.7 FAQs About Optical Modules........................94 Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 7 B.1 A-E................................97 B.2 F-J................................98 B.3 K-O................................98 B.4 P-T................................98 B.5 U-Z................................100 C Acronyms and Abbreviations..................101 C.1 A-E................................101 C.2 F-J................................102 C.3 K-O................................104 C.4 P-T................................104 C.5 U-Z................................106 Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 8: Product Overview

    1 Product Overview Product Overview The FusionServer G5500 V7 server (G5500 V7 for short) is a heterogeneous computing server that is optimized in HPC as well as data training and inference for deep learning for scenarios such as AI, HPC, cloud computing, and big data analytics.
  • Page 9: Features

    RAID 0, 1, 1E, 10, 5, 50, 6, and 60, depending on the RAID controller card used. It also uses a supercapacitor to protect the RAID cache data against power failures. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 10 ® ● Intel Software Guard Extensions (SGX) technology allows applications to run in their own independent space without being affected by other software running in the system, thereby enhancing security. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 11 The improved thermal design with energy-efficient fans ensures optimal heat dissipation and reduces system power consumption. ● The server is protected with power capping and power control measures. ● Staggered spinup of drives reduces the server boot power consumption. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 12: Physical Structure

    Power adapter board Chassis GPU beam Supercapacitor Air duct Cable management arm M.2 SSD (CMA) PCIe plug-in RAID Riser card of a PCIe plug- controller card in RAID controller card Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 13 Left mounting ear plate 3.5" drives Fan modules Right mounting ear plate Fan module frame Cable management arm (CMA) CPU heat sinks Mainboard Memory modules TPM/TCM BMC card OCP cards NIC riser modules Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 14: Logical Structure

    FusionServer G5500 V7 Server Technical White Paper 4 Logical Structure Logical Structure Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 15 FusionServer G5500 V7 Server Technical White Paper 4 Logical Structure Figure 4-1 Logical structure 1 (configuration with 24 x 3.5" drives + 8 x dual-width GPUs + 1 x PCIe switch board) Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 16 FusionServer G5500 V7 Server Technical White Paper 4 Logical Structure Figure 4-2 Logical structure 2 (configuration with 20 x 2.5" drives + 10 x dual-width GPUs + 1 x PCIe switch board) Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 17 CPU 1 and CPU 2 support a maximum of three OCP 3.0 X8 NICs, depending on the configurations. ● The BMC management chip integrated on the mainboard supports a video graphics array (VGA) port, a management network port, and a serial port. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 18: Hardware Description

    5.4 Memory 5.5 Storage 5.6 Network 5.7 I/O Expansion 5.8 PSUs 5.9 Fan Modules 5.10 Boards 5.1 Front Panel 5.1.1 Appearance ● 24 x 3.5" drive configuration Figure 5-1 Front view Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 19: Indicators And Buttons

    Positions of Indicators and Buttons ● 24 x 3.5" drive configuration Figure 5-3 Indicators and buttons on the front panel Fault diagnosis LED Power button/indicator Health status indicator Unit identification light (UID) button/indicator Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 20 Fault ● ---: The device is operating properly. diagnosis LED ● Error code: A component is faulty. For details about error codes, see the FusionServer GPU Server iBMC Alarm Handling. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 21 ● You can press this button to turn on or off the UID indicator. ● You can press and hold down this button for 4 to 6 seconds to reset the iBMC. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 22: Ports

    ● Steady green: The server configuration file is being copied from the USB device or the job is successfully completed. 5.1.3 Ports Port Positions ● 24 x 3.5" drive configuration Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 23 VGA port Port Description Table 5-2 Ports on the front panel Port Type Description Note Quantity VGA port DB15 Used to connect a display terminal, such as a monitor or KVM. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 24 However, the USB 3.0 port must comply with the USB specifications. To run advanced peripherals, such as external CD/DVD drives, an external power supply is required. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 25: Rear Panel

    FlexIO card 3 FlexIO card 2 Slot 21 (PCIe 5.0 x16) FlexIO card 1 Slot 20 (PCIe 5.0 x16) Slot 19 (PCIe 5.0 x16) Slot 18 (PCIe 5.0 x16) BMC card Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 26: Indicators And Buttons

    Figure 5-8 Indicators on the rear panel Data transmission status Connection status indicator indicator of the of the management management network port network port Serial port indicators UID indicator NOTE Reserved and unavailable currently. PSU indicator Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 27 ● Off: The device is not being located. ● Blinking or steady blue: The device is being located. NOTE You can control the UID indicator status by pressing the UID button or using the iBMC. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 28: Ports

    NOTE The management network port is a GE port that supports 100 Mbit/s and 1000 Mbit/s auto-negotiation. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 29: Processors

    Processors of the same model must be used in a server. ● For details about the optional components, consult your local sales representative or see "Search Parts" in the Compatibility Checker. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 30: Memory

    5.4.1 DDR5 Memory 5.4.1.1 Memory Identifier You can determine the memory module properties based on the label attached to the memory module and the following figures and tables. Figure 5-11 Memory identifier Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 31: Memory Subsystem Architecture

    The server provides 32 memory interfaces. Each processor integrates eight memory channels. Install the memory modules in the primary memory channels first. If the primary memory channel is not populated, the memory modules in secondary memory channel cannot be used. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 32 DIMM071(P) CPU 2 A (primary) DIMM100(A) DIMM101(I) B (primary) DIMM110(B) DIMM111(J) C (primary) DIMM120(C) DIMM121(K) D (primary) DIMM130(D) DIMM131(L) E (primary) DIMM140(E) DIMM141(M) F (primary) DIMM150(F) DIMM151(N) G (primary) DIMM160(G) Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 33: Memory Compatibility

    Each memory channel supports more than eight ranks for load-reduced DIMMs (LRDIMMs). NO TE A quad-rank LRDIMM generates the same electrical load as a single-rank RDIMM on a memory bus. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 34: Dimm Installation Rules

    A server supports up to 32 DDR5 memory modules. To maximize performance, it is advised to use balanced memory configuration. Observe the memory module installation rules when configuring memory modules. For details, see the Server Assembly Guide. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 35 Technical White Paper 5 Hardware Description NO TICE At least one DDR5 memory module must be installed in the primary memory channels corresponding to each CPU. Figure 5-12 Positions of memory modules Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 36: Memory Protection Technologies

    FusionServer G5500 V7 Server Technical White Paper 5 Hardware Description Figure 5-13 DDR5 memory installation guidelines (two processors) 5.4.1.6 Memory Protection Technologies DDR5 DIMMs support the following memory protection technologies: Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 37: Storage

    Write Data CRC Protection ● Adaptive Data Correction - Single Region (ADC-SR) ● Adaptive Double Device Data Correction - Multiple Region (ADDDC-MR) 5.5 Storage 5.5.1 Drive Configuration and Drive Numbering Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 38: 24 X 3.5" Drive Configuration

    ● a: The PCIe plug-in RAID controller card is installed in slot 26 by default. ● For details about the optional components, consult your local sales representative or see "Search Parts" in the Compatibility Checker. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 39 RAID controller card. This section uses the drive numbers identified by a RAID controller card that adopts the default cabling described in section "Internal Cabling" in the FusionServer G5500 V7 Server Maintenance and Service Guide. Drive numbering of the 24 x 3.5" drive switch model configuration in...
  • Page 40 ● For details about the optional components, consult your local sales representative or see "Search Parts" in the Compatibility Checker. Drive numbering of the 24 x 3.5" drive pass-through model configuration in Table 5-7 Figure 5-15 Drive numbering Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 41 Drive Number Identified on the iBMC WebUI by the RAID Controller Card For details about the optional components, consult your local sales representative or see "Search Parts" in the Compatibility Checker. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 42: 20 X 2.5" Drive Configuration

    RAID controller card that adopts the default cabling described in "Internal Cabling" in the FusionServer G5500 V7 Server Maintenance and Service Guide. Drive numbering of the 20 x 2.5" drive (8 x SAS/SATA + 12 X NVMe) configuration in...
  • Page 43 Drive Number Drive Number Displayed Drive Number Identified on the iBMC WebUI by the RAID Controller Card Consult your local sales representative or see "Search Parts" in the Compatibility Checker. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 44: Drive Indicators

    Data on the secondary drive is being Hz synchronously rebuilt. Red steady on A drive in a RAID array is removed. Steady on Red steady on The drive is faulty. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 45 The NVMe drive is not detected. Steady on The NVMe drive is detected and operating properly. Blinking at 4 Hz Data is being read from or written to the NVMe drive. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 46: Raid Controller Card

    A maximum of 16 PCIe slots are supported. ● For details about the optional components, consult your local sales representative or see "OS and Parts Compatibility" in the Compatibility Checker. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 47: Pcie Slots

    IB cards at both ends of the network connection are the same. For details, contact technical support. 5.7.2 PCIe Slots PCIe Slots Figure 5-19 PCIe slots Figure 5-20 Built-in PCIe slot Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 48 The PCIe riser card is installed in I/O module 1 of the switch model. It provides PCIe slots 18, 19, 20, and 21. Figure 5-22 PCIe riser card ● PCIe riser card of the pass-through model Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 49 It is installed in the built-in riser module and provides PCIe slot 26. Figure 5-24 PCIe riser card ● PCIe riser card of the front GPU riser module It provides PCIe slots 23 and 25. Figure 5-25 PCIe riser card Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 50: Pcie Slot Description

    PE 4 FHFL dual- (x16) width Slot 14 PCIe 5.0 CPU 2 PE 4 FHFL dual- (x16) width Slot 16 PCIe 5.0 CPU 2 PE 4 FHFL dual- (x16) width Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 51 CPU 2 PE 1 (0 OCP 3.0 card 2 x16 (x8) to 7) specifica tions FlexIO PCIe 5.0 CPU 2 PE 1 OCP 3.0 card 3 x16 (x8) (8-15) specifica tions Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 52 Rear (x16) width Module Slot 5 PCIe 5.0 CPU 1 PE 1 FHFL dual- (x16) width Slot 7 PCIe 5.0 CPU 1 PE 1 FHFL dual- (x16) width Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 53 PCIe 5.0 CPU 1 PE 1 FHFL riser dual- card (x16) width supporte Slot 25 PCIe 5.0 CPU 2 PE 3 FHFL d by the dual- front (x16) width module Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 54 Slot 1 PCIe 5.0 CPU 1 PE 1 FHFL Card dual-width Supported (x16) by the Slot 3 PCIe 5.0 CPU 1 PE 1 FHFL Rear GPU x16 (x16) dual-width Module Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 55 ● The FHFL PCIe slots are compatible with FHFL PCIe cards, FHHL PCIe cards, and HHHL PCIe cards. ● The maximum power supply of each PCIe slot is 75 W. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 56: Psus

    For details, see FusionServer Servers Power Calculator. ● For details about the optional components, consult your local sales representative or see "Search Parts" in the Compatibility Checker. Figure 5-26 Positions of PSUs Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 57: Fan Modules

    Fan modules of the same P/N code must be used in a server. Figure 5-27 Positions of fan modules of a server with 24 x 3.5" drives (example) 5.10 Boards Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 58: Mainboard

    OCP 3.0 NIC 3 connector RAID controller card low- (OCP3 CONN/J7023) speed signal connector (RAID MIS/J7017) OCP 3.0 NIC 2 UBC OCP 3.0 NIC 2 connector connector (UBC2-2B/ (OCP2 CONN/J7016) J6071) Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 59 Fan board power connector Fan board power 1 (FAN PWR_1/J7010) connector 2 (FAN PWR_2/ J7006) PSU backplane input Copper bar power power connector (PWR IN/ connector (PWR GND/ J6093) J7008) Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 60: Drive Backplane

    Low-speed signal (REAR BP0/1 J33) connector (REAR BP1/ J38) Low-speed signal UBC 4 high-speed connector (MAIN connector (J5) BOARD/J40) Power connector (24HDD mini-SAS HD connector POWER MAINBOARD/ (REAR BP PORTC/J36) J42) Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 61 UBC connector 2-A (UBC2-B/J2) (UBC2-A/J1) Backplane signal cable Power connector connector (HDD BP/J40) (HDD_POWER/J41) mini-SAS HD connector UBC connector 2-D (PORT A/J13) (UBC2-D/J4) mini-SAS HD connector UBC connector 1-F (PORT B/J14) (UBC1-F/J12) Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 62: Fan Board

    Fan connector (FAN1B/J7) Fan connector (FAN2B/J8) Fan connector (FAN2A/J6) Fan board power connector 1 (POWER CONN1/J4) Fan connector (FAN3B/ Fan connector (FAN3A/J9) J11) Fan connector (FAN4B/ Fan connector (FAN4A/ J12) J10) Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 63: Psu Backplane

    Reserved and unavailable currently. 5.10.4 PSU Backplane Figure 5-32 PSU backplane Power connector (HDD BP/ Power connector J100) (RSW-2&MB/J102) Power connector Guide sleeve (J108) (RSW-1&RISER/J101) Spurious signal connector (J103) Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 64: Pcie Switch Board

    J133) J134) CEM connector (PCIE CEM connector (PCIE SLOT7 X16/J14) SLOT5 X16/J13) CEM connector (PCIE CEM connector (PCIE SLOT3 X16/J12) SLOT1 X16/J11) UBC high-speed connector UBC high-speed connector (UBC1-5B/J137) (UBC1-5A/J136) Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 65 GPU power connector (GPU PWR CONN12/J116) (GPU PWR CONN14/J117) GPU power connector UBC high-speed connector (GPU PWR CONN16/J118) (UBC5-HDDBP/J141) UBC high-speed connector UBC high-speed connector (UBC2-4A/J139) (UBC2-4B/J138) Low-speed signal connector (DPU/J144) Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 66: Pcie Pass-Through Board

    Spurious connector for the CEM connector 4 (PCIE riser card (MISC SLOT7 x16 (UBCDD1-3)/ SLOT9/J1) J13) CEM connector 3 (PCIE CEM connector 2 (PCIE SLOT5 x16 (UBCDD1-1)/ SLOT3 x16 (UBCDD1-4)/ J12) J11) Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 67: Ssd Adapter Board

    J102) CONN14/J116) GPU power cable Power connector (PWR connector 8 (GPU PWR CONN2/J4) CONN16/J117) 5.10.7 M.2 SSD Adapter Board Figure 5-35 M.2 adapter board Signal connector (J1) High-speed connector (J2) Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 68: Product Specifications

    ● Min. 1.875 MB L3 cache per core. ● Max. 350 W thermal design power (TDP). NOTE The preceding information is for reference only. For details, see "Search Parts" in the Compatibility Checker. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 69 – A server must use DDR5 DIMMs of the same P/N code. NOTE The preceding information is for reference only. For details, see "Search Parts" in the Compatibility Checker. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 70 RAID level migration, and drive roaming. – The RAID controller card supports a supercapacitor for power-off protection to ensure user data security. – The PCIe plug-in RAID controller card occupies one PCIe slot. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 71 – One built-in PCIe plug-in RAID controller card slot. For details, see 5.7.2 PCIe Slots 5.7.3 PCIe Slot Description. NOTE The preceding information is for reference only. For details, see "Search Parts" in the Compatibility Checker. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 72 Security feature ● Power-on password ● Administrator password ● TPM (for China and outside China)/TCM (only for China) ● Secure boot ● Front bezel (optional) ● Chassis cover opening detection Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 73: Environmental Specifications

    Maximum growth rate of the corrosive product thickness: contaminant ● Copper corrosion rate test: 300 Å/month (meeting level G1 requirements of the ANSI/ISA-71.04-2013 standard on gaseous corrosion) ● Silver corrosion rate test: 200 Å/month Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 74 6 months in unpacked/packed and powered-off state ● The maximum preservation duration is determined according to the preservation specifications provided by drive vendors. For details, see the manuals provided by drive vendors. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 75: Physical Specifications

    – A ball bearing rail kit applies to cabinets with a distance of 609 mm to 950 mm (23.98 in. to 37.40 in.) between the front and rear mounting bars. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 76 57 kg (125.66 lb) ● Packing materials: 24 kg (52.91 lb) Power consumption Power consumption parameters vary with server configurations (including ErP-standard configurations). For details, see FusionServer Servers Power Calculator. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 77: Software And Hardware Compatibility

    ● If the customer has requirements on hardware performance consistency, specify the specific configuration requirements (for example, specific drive models, RAID controller cards, or firmware versions) in the presales phase. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 78: Safety Instructions

    Discontinue any dangerous operations and take protective measures. Report anything that could cause personal injury or device damage to a project supervisor. ● Do not move devices or install cabinets and power cables in hazardous weather conditions. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 79 Fasten the strap buckle and ensure that the ESD wrist strap is in contact with your skin. Insert the ground terminal attached to the ESD wrist strap into the jack on the grounded cabinet or chassis. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 80 Transportation precautions include but are not limited to: ● The logistics company engaged to transport the device must be reliable and comply with international standards for transporting electronics. Ensure that the Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 81: Maintenance And Warranty

    People's Republic of China (AQSIQ) For more information about safety instructions, see Server Safety Information. 8.2 Maintenance and Warranty For details about the maintenance policy, visit Customer Support Service. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 82 FusionServer G5500 V7 Server Technical White Paper 8 Safety Instructions For details about the warranty policy, visit Warranty. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 83: System Management

    ● Security management – Software image backup improves system security. Even if the running software breaks down, the system can be started from the backup image. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 84 Compared with the standard edition, the iBMC advanced edition provides more advanced features, such as: – Implements the OS deployment using Redfish. – Collect the original data of intelligent diagnosis using Redfish. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 85: Certifications

    FusionServer G5500 V7 Server Technical White Paper 10 Certifications Certifications Country/Region Certification Standard China GB 4943.1-2022 GB/T 9254.1-2021(Class A) GB 17625.1-2022 Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 86: Waste Product Recycling

    FusionServer G5500 V7 Server Technical White Paper 11 Waste Product Recycling Waste Product Recycling If product users need product recycling service provided by xFusion after products are scrapped, contact technical support for services. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 87: A Appendix

    FusionServer G5500 V7 Server Technical White Paper A Appendix Appendix A.1 Chassis Label Information A.1.1 Chassis Head Label Figure A-1 Chassis head label Nameplate Certificate Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 88: Nameplate

    A.1.1.1 Nameplate Figure A-2 Sample nameplate Table A-1 Nameplate description Description Server model For details, see Nameplate. Device name Power supply requirements Vendor information Certification marks Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 89: Certificate

    Table A-3 Certificate number description Description P: a fixed value for this digit Z: a fixed value for this digit ● Y: a server ● B: a semi-finished server ● N: a spare part Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 90: Quick Access Label

    ● Letters J to N indicate 18:00 to 22:00. ● Letters P to Q indicate 23:00 to 24:00. Serial number (two characters). Manufacturing serial number (five characters). A.1.1.3 Quick Access Label Figure A-5 Quick access label example Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 91: Chassis Internal Label

    QR codes of technical resources. The pictures are for reference only. For details, see the actual product. ● The quick start guide is optional. For details, see the actual product. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 92: Chassis Tail Label

    SN is required when you contact technical support. SN example 1 SN example show two SN examples. ● SN example 1 Figure A-8 SN example 1 ● SN example 2 Figure A-9 SN example 2 Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 93 Sequence number (six characters). RoHS compliance (one character). Y indicates environmental-friendly processing. Internal model, that is, product name. The actual board model format may vary. For details, see the actual board model. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 94: Operating Temperature Limitations

    270 W or lower than 270 W and the number of front drives is less than or equal to 16, A100/H100 GPUs are supported. ● A40 GPUs are not supported. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 95: Nameplate

    BMC card 1711 chip SSD Max Temp Maximum SSD temperature (reported by BMA) CPUN Core Temp CPU core temperature CPUN N indicates the CPU number. The value is 1 or Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 96 CPUN Prochot CPU Prochot CPUN N indicates the CPU number. The value is 1 or CPUN VCCIN CPU VCCIN voltage Mainboard N indicates the CPU number. The value is 1 or Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 97 N indicates the CPU number. The value is 1 or PSN VIN PSU N input voltage PSU N N indicates the PSU number. The value ranges from 1 to 4. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 98 ID. The value is 1A, 1B, 2A, 2B, 3A, 3B, 4A, or 4B. FANN F Presence Fan module presence Fan module N N indicates the fan module ID. The value is Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 99 The value is 1 or 2. Riser$ Temp Riser card temperature Riser card SAS Cable Entity presence SAS cable on the mainboard LCD Status LCD health status LCD Presence LCD presence Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 100 OCP card optical module OCP 3.0 NIC temperature sensor OCP$ Temp OCP card chip OCP 3.0 NIC temperature sensor SSD Disk$ Temp SSD temperature GPU$ Power GPU power GPU$ Temp GPU temperature Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 101: Faqs About Optical Modules

    Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 102 Some optical modules that have not been tested for electromagnetic compatibility are not designed in compliance with interference to nearby EMC standards and have low anti-interference devices. capability. Additionally, they bring electromagnetic interference to nearby devices. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 103 As a result, the optical modules cannot work server. properly. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 104: B Glossary

    DEC. Ethernet uses the Carrier Sense Multiple Access/Collision Detection (CSMA/CD) access method and allows data transfer over various cables at 10 Mbit/s. The Ethernet specification is the basis for the IEEE 802.3 standard. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 105: F-J

    It seals the front and rear of the chassis to ensure optimal ventilation and electromagnetic compatibility (EMC). Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 106 A special computer that provides services for clients over a network. System event log (SEL) Event records stored in the system used for subsequent fault diagnosis and system recovery. Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 107: U-Z

    60297-1 to measure the height of a cabinet, chassis, or subrack. 1 U = 44.45 mm = 1.75 in. UltraPath Interconnect (UPI) A point-to-point processor interconnect ® developed by Intel Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 108: C Acronyms And Abbreviations

    Instruction Set Address Resolution Protocol Advanced Vector Extensions backup battery unit BIOS Basic Input/Output System Baseboard Management Controller China Compulsory Certification calendar day Conformite Europeenne Common Information Model command-line interface Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 109: F-J

    Enclosure ID (backplane ID) European Efficiency enterprise resource planning European Telecommunication Standards C.2 F-J FB-DIMM Fully Buffered DIMM Fiber Channel Federal Communications Commission FCoE Fibre Channel Over Ethernet File Transfer Protocol Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 110 Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input/output operations per second Internet Protocol intelligent power capability IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 111: K-O

    LAN on motherboard media access control module management controller next business day NC-SI Network Controller Sideband Interface Open Compute Project C.4 P-T PCIe Peripheral Component Interconnect Express Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 112 SDDC single device data correction SERDES serializer/deserializer SGMII serial gigabit media independent interface serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol serial over LAN Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 113: U-Z

    Union Bus Connector UBC DD Union Bus Connector Double Density UDIMM unbuffered dual in-line memory module UEFI Unified Extensible Firmware Interface unit identification light Underwriter Laboratories Inc. UltraPath Interconnect Universal Serial Bus Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 114 Interference by Information Technology Equipment Video Graphics Array VLAN Virtual local area network Voltage regulator-down VROC Virtual RAID on CPU WEEE Waste Electrical and Electronic Equipment WSMAN Web Service Management Issue 02 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.

Table of Contents