7.4.1-2. Equipment and Chart Setting

①Still mode:
(For inspection, Adjustment repeating "Take a picture - Inspection -Adjustment" as a cycle.)
(2) Checking Chart
(1) LED lamps
②Real Time mode:
(2) Checking Chart
(1) LED lamps
IMPORTANT (About chart) : In this model, there are 2 kinds of Checking Charts are used.
Compact Checking Chart
- For
TELE
edge -
Size : A3 (H 297mm x 430mm )
(1)
Install LED lights left and right symmetrically as uneven
illumination does not occur.
* The standard illuminance on the surface of all the 5 points of
the chart described as shown in the figure with red marking is
1500±150 lux.
(2)
Fix the Camera body and Lens to check on a tripod, and set the
distance from the Chart as below.
TELE : About 3,000mm
WIDE : About 1,100mm
NOTE:
* About distance setting between chart and camera, the composition
(Frame of "3:2" line comes to edge of the screen) have higher priority than distance.
Refer to the "7.4.1-4.2 Master Body Position", in details.
* Housing space for performance checking is generally recommended
H:1,500mm x W:2,500mm x D:9,000mm or over.
(4)
After fine tune the installation position of the tripod;
[For Still mode ]
[For Real-time mode] Connect HDMI cable to Capture Board and transfer video data. Branch data from
Execute Resolution check software.
(5)
* Shoot the Chart and execute resolution checking by analyzing the chart picture
Connect HDMI cable to Monitor and display video data.
(6)
(3) Lens and Master Body (e.g.DC-GH5)
(Adjusted results are reflected and displayed in real time.)
(3) Lens and Master Body (e.g.DC-GH5)
Download from TSN
website and print it on A3
size paper and past on
the plastic white board on
a vertical wall.
[Compact Checking Chart - Camera]
[Checking Chart (SUKZ000059) - Camera]
Connect USB cable to PC.
the Capture Board to the PC and Monitor.
Also connect USB cable from Capture board to PC.
(4) USB cable
(5) PC Software
(6) Monitor
HDMI cable
USB cable
(4) Capture Board
Checking Chart (SUKZ000059)
- For
WIDE
edge -
Size: H 960mm x W 1440mm or over
illuminance measurement point
(Example: Compact Checking Chart)
21
(*not necessary)
(5) PC Software
Assemble it after
purchase/delivered.
Paste the chart with
plastic white board on
a vertical wall.