7.4. Procedure of Inspection and Adjustment

7.4.1. Equipment and Chart Setting

(2) Checking Chart
(1) LED lamps
Install LED lights left and right symmetrically as uneven
(1)
illumination does not occur.
* The standard illuminance on the surface of all the 5 points of
the chart described as shown in the figure with red marking is
1500±150 lux.
Assemble the Checking Chart and paste the Chart with plastic
(2)
white board on a vertical wall.
* Checking Chart size : H 960mm x W 1440mm
Fix the Camera body and Lens to check on a tripod, and set the
(3)
distance from the Chart as below.
TELE end : About 4,200mm
WIDE end : About 960mm
* Housing space for performance checking is recommended
H:1,500mm x W:2,500mm x D:5,000mm and more.
After fine tune the installation position of the tripod, connect USB cable to PC and execute Resolution Check
(4)
software.
(3) Lens and Master Body(DC-S1R)
26
USB cable
(4) PC Software
illuminance measurement point