7.4. Procedure of Adjustment

7.4.1. Equipment and Chart Setting

(2) Checking Chart
(1) LED lamps
Install LED lights left and right symmetrically as uneven
(1)
illumination does not occur.
* The standard illuminance on the surface of all the 5 points of
the chart described as shown in the figure with red marking is
1500±150 lux.
Assemble the Checking Chart and paste the Chart with plastic
(2)
white board on a vertical wall.
* Checking Chart size : H 960mm x W 1440mm
Fix the Camera body and Lens to check on a tripod, and set the
(3)
distance from the Chart as below.
About 2,000mm
* Housing space for performance checking is recommended
H:1,500mm x W:2,500mm x D:5,000mm and more.
After fine tune the installation position of the tripod, connect HDMI cable to Capture Board and transfer video data.
(4)
Branch data from the Capture Board to the PC and Monitor.
Connect HDMI cable to Monitor and display video data.
(5)
Connect USB cable to PC and execute Resolution Check software.
(6)
* Shoot the Chart and execute Resolution checking by analyzing the chart picture
(3) Lens and Master Body(DC-S1R)
22
(5) Monitor
HDMI cable
USB cable
(4) Capture Board
(6) PC Software
illuminance measurement point