Material A Usage - Graco SuperCat 232096 Instruction Manual

Proportioner packag
Table of Contents

Advertisement

Material Usage Key 4, Level 3

Material A Usage

Default Setting: see chart below for default settings
depending on the pump ratio
Purpose
To set the cycles per gallon/liter for proportioner side
A. This allows the control to calculate the usage of
material A.
Access
In setup level 3, press key 4 on the keypad to access
the Material A Usage function.
Keypad Display
The key 4 light is green and 3 appears in the keypad
setup level position. See Fig. 66.
System Schematic Panel
The pump A light blinks. See Fig. 67.
Changing Values
See the chart below for settings for the fixed ratio
pumps.
Press the arrow keys to change the cycles per gallon/
liter for proportioner side A.
Fixed
Dura-Flo
Ratio
Pump
Model
(Side A)
2:1
1200
3:1
900
4:1
1200
WARNING
COMPONENT RUPTURE HAZARD
Do not exceed the 5000 psi (34 MPa,
345 bar) Maximum Working Fluid Pres-
sure of the system. Over-pressurizing
can rupture components and cause
serious injury.
Setup Functions
Cycles/
Cycles/
Gallon
Liter
12.5
3.3
16.7
4.4
12.5
3.3
Fig. 66
Material A Usage
A
B
A B
Fig. 67
4
A/B S
A
A/B
S
B
B AB
A
A
B