Option 3, for continuous applications when
reservoirs are filled manually: Install additional
circulation pumps to create a loop from the reser-
voirs, through the circulation pumps, through the
heaters, and back to the reservoirs. See Fig. 7. Fill
the reservoirs manually. Set the heaters to the
Reservoir
Circulation
Pump
NOTE: This configuration is used both on the
A Component and on the B Component sides.
Fig. 7
Installation
Proportioner
Pump
Heater
desired temperature and circulate the fluid using
the circulation pumps. When the fluid temperature
in the reservoirs reaches the desired level, begin
spraying. Add material as required. Fluid will
continue to circulate. With this option, continuous
spraying is possible.
Mix Manifold
Fluid Cabinet
Gun
8685A