Section 3 - Operation
Batteries do not fully charge.
If the batteries are charged overnight, make sure the
AC supply is not being switched off at night with other
building items. Check battery condition and for dead
cells or reduced capacity. Replace charger only if other
problems are not found.
The AC line circuit breaker or fuse is blown.
A defective circuit breaker or fuse, an overloaded
circuit, or a charger problem can cause this condition.
Try connecting the charger to a different AC outlet
(on a different circuit) in the building. If the AC supply
checks good, the charger should be replaced.
SJIII DC Electric
EE-Rated Aerial Platforms
Do not charge batteries in hazardous
area! The EE-rating of an aerial platform
does not include the charging of batteries.
1.
Move the aerial platform to an area designated for
battery charging. Refer to NFPA 505 for charging
setup. NFPA 505 is a publication of the National
Fire Protection Association, Inc., Batterymarch
Park, Quincy, MA 02269 (USA).
The charging temperature for an EE-rated
aerial platform is limited 40°C ambient.
2.
Charge batteries. Refer to
battery charging operation. When charge cycle is
completed, disconnect charger plug from battery
tray.
Battery Maintenance
WARNING
NOTE
Section 3.13-2
Page 59