Strip the insulation of the single conductors by 12 mm. Lift to open the AC ter-
minal's operating lever and insert the stripped single conductor into the slot
provided, all the way up to the stop. Then close the operating lever until it en-
gages.
IMPORTANT!
The PEN conductor must be produced with ends that are permanently marked
blue, according to the national provisions, and have a cross section of 10 mm².
12
166
Fasten the PC board with the 4 screws
(TX20) supplied and tighten to a
torque of 1.2 Nm.
Fasten the PEN conductor to the third
input of the ground electrode terminal
from below using a screwdriver (TX20)
and a torque of 1.8 – 2 Nm.