Specifying the charging range
It is possible to define a charging range with a min. and max. charging limit. In
this case, it is not possible for the battery to discharge.
Limit
discharge power
1.
Min. charging power
2.
Max. charging power
Specifying the discharging range
It is possible to define a discharging range with a min. and max. discharging limit.
In this case, it is not possible for the battery to charge.
Limit
Max. discharge
discharge power
power 3000 W
1.
Max. discharging power
2.
Min. discharging power
Specifying a defined charging power
A defined charging power can be specified by setting the min. and max. charging
power to the same value.
Limit
discharge power
1.
Min. charging power
Max. charging power
2.
0 W
Min. charging
power 500 W
500 W
03:00 – 04:00
Mo Tu We Th Fr Sa Su
3800 W
03:00 – 04:00
Mo Tu We Th Fr Sa Su
0 W
Min. discharge
power 1000 W
3000 W
13:00 – 14:00
Mo Tu We Th Fr Sa Su
1000 W
00:00 – 23:59
Mo Tu We Th Fr Sa Su
0 W
3000 W
03:00 – 04:00
Mo Tu We Th Fr Sa Su
3000 W
03:00 – 04:00
Mo Tu We Th Fr Sa Su
Max. charging
Limit
power 3800 W
charging power
Limit
charging power
Min./Max. charging
Limit
power 3000 W
charging power